Compact Fieldbus Power Hub Motherboard with Common Interface MBHC-FB-4R*

Compact Fieldbus Power Hub Motherboard with Common Interface MBHC-FB-4R*
Compact Fieldbus Power Hub Motherboard with Common Interface MBHC-FB-4R*

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 64475
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 4 segments, redundant, individual modules per segment
  • Supports all PLC and PCS hosts
  • High-power trunk: Live work on devices in any hazardous area
  • Best quality, smallest size and lowest heat dissipation
  • For FOUNDATION Fieldbus H1
  • Optional advanced diagnostics
  • Passive impedance for high reliability
  • Supports Ex ic voltage limitation
  • Installation in Zone 2/Div. 2
  • Spring terminals or screw terminals selectable
Параметр Значение
Общие характеристики
Артикул 64475
Ambient temperature -40 ... 70 °C (-40 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Degree of protection IP20
Connection redundant
Mass approx. 580 g
Rated voltage 19.2 ... 35 V SELV/PELV
Electromagnetic compatibility NE 21:2011
Relative humidity < 95 % non-condensing
Mounting DIN mounting rail
Pollution degree max. 2, according to IEC 60664
Marking II 3G Ex nA IIC T4 Gc
Vibration resistance 1 g , 10 ... 150 Hz
Connection type plug-in terminals , spring terminal and screw terminal
Housing material Polycarbonate
Core cross-section 2.5 mm
IECEx approval IECEx TUN 13.0037X
Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Approved for Ex nA IIC T4 Gc
Rated current 12 A
FM approval CoC 3024816, CoC 3024816C
Directive 2014/30/EU EN 61326-1:2013
Shock resistance 10 g , 11 ms
Certificate TÜV 10 ATEX 555761X
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
Power dissipation typ. 0.4 W per segment
Fault signal VFC alarm 1 A, 50 V DC, normally closed
Design / Mounting Motherboard based
Number of segments 4 redundant
Fieldbus segment/Fieldbus segment functional insulation acc. to IEC 62103, rated insulation voltage 50 V
Corrosion resistance acc. to ISA-S71.04-1985, severity level G3
Marine approval DNV A-14038
Host-side general purpose host
Terminating resistor 100 Ω integrated
Fieldbus segment/Supply functional insulation acc. to IEC 62103, rated insulation voltage 250 V