PROFIBUS Power Hub, Gateway Module HD2-GTR-4PA

PROFIBUS Power Hub, Gateway Module HD2-GTR-4PA
PROFIBUS Power Hub, Gateway Module HD2-GTR-4PA

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 28138
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • PROFIBUS DP V1 / For 4 segments PA
  • Couples PROFIBUS PA devices transparently to PROFIBUS DP
  • Optional redundant configuration
  • Installation in Zone 2/Class I, Div. 2
  • Up to 12 Mbit/s, auto adapting
  • For redundant and non-redundant masters
  • Supports Flying Redundancy (FR)
  • Cyclic/acyclic data exchange
Параметр Значение
Общие характеристики
Артикул 28138
Ambient temperature -40 ... 60 °C (-40 ... 140 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Degree of protection IP20
Connection 9-pin Sub-D socket
Mass 250 g
Rated voltage 19.2 ... 35 V DC
Electromagnetic compatibility NE 21:2011
Relative humidity < 95 % non-condensing
Mounting motherboard mounting , mounting in any orientation
Housing width 40 mm
Housing depth 128 mm
Housing height 106 mm
Pollution degree max. 2, according to IEC 60664
Marking II 3 G Ex nA IIC T4 Gc
Protocol PROFIBUS DP V1
Vibration resistance 1 g , 10 ... 150 Hz
Housing material Polycarbonate
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
LED red yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available
Rated current 160 ... 90 mA
Directive 2014/30/EU EN 61326-1:2013
Shock resistance 15 g 11 ms
Certificate TÜV 04 ATEX 2500 X
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
Power dissipation 3 W
Galvanic isolation IEC 62103
Design / Mounting Motherboard based
LED Seg 1...4 red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error
Corrosion resistance acc. to ISA-S71.04-1985, severity level G3
FM certificate FM 19 US 0015 X and FM 19 CA 0011 X
FM marking AEx/Ex ec IIC T4
IECEx certificate IECEx TUN 13.0038X
IECEx marking Ex nA IIC T4 Gc
Marine approval DNV A-14038
Fieldbus standard IEC 61158-2
LED PWR green: Power on
All circuits/FE functional insulation acc. to IEC 62103, rated insulation voltage 50 V
Directive 73/23/EEC EN 50178 (identical to EN 62103)
PROFIBUS DP/Supply functional insulation acc. to IEC 62103, rated insulation voltage 50 V
LED DP/ERR red 2 Hz flashing: DP error ; red: Hardware error
CH/PROFIBUS DP functional insulation acc. to IEC 62103, rated insulation voltage 50 V
CH/CH functional insulation acc. to IEC 62103, rated insulation voltage 50 V