  • For 20 analog or 40 digital channels
  • Sensors in Zone 0/Div. 1 (depending on module assembly)
  • Installation in Zone 2, Div. 2 or safe area
  • HART communication via service bus
  • For FOUNDATION Fieldbus H1
  • Configured via the process control system
  • Non-volatile memory for configuration and parameter settings
  • Quick communication set-up
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage
Параметр Значение
Общие характеристики
Артикул 56294
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Degree of protection IP20
Connection plug-in screw connector on the backplane
Rated voltage 24 V DC
Power consumption max. 39 W , available output power for Zone 2 applications 5 W (5V), 20 W (12V), else 5 W (5V), 35 W (12V)
Protocol H1 to IEC 1158-2
Dimensions 275 x 127 mm (10.8 x 5 inch)
LED indicator Com unit LB8110*: LED green (power supply): on = operating, fast flash = cold start LED red (collective alarm): on = internal fault, flashing = no fieldbus LED yellow (operating mode): flashing = active Power supply LB9006C: LED green (power supply): off in case of loss of 24 V or 12 V or 5 V I/O modules (refer to the table with compatible modules for order codes): Power LED green: supply Diagnostic LED red: module fault, red flashing: communication error Status LED red: line fault Status LED yellow: signal (Live Zero status)
Group, category, type of protection, temperature class II 3 G Ex nA IIC T4
Directive 94/9/EC EN 60079-0 , EN 60079-15
Directive 2004/108/EC EN 61326-1
Statement of conformity PF 08 CERT 1234 X
Baud rate 31.25 kBit/s , MBP
Number of stations per bus line 1 or 2, depending on the required response times
Bus length max. 1900 m (must not be exceeded by the sum of all trunk and spur lines)
Addressing via PCS (software)
Station connection directly at the trunk or via spur protector
Number of channels per station max. 20 analog, max. 40 digital
Auxiliary energy 24 V DC Trunk load 10 mA according to FF standard.
Spur length max. 120 m (depending on the number of field devices. Modular I/O station = 1 field device)