  • A/B slave with extended addressing possibility for up to 62 slaves
  • Inputs for 3-wire sensors
  • Outputs for DC roller motors (drum motors)
  • Connection of motors and sensors via M8 connectors
  • Configurable start/stop ramps
  • Communication monitoring
  • Power supply of the inputs and outputs from the external auxiliary voltage
  • Function display for bus, external auxiliary voltage, in- and outputs
  • Cable piercing method with gold plated contact pins
Параметр Значение
Общие характеристики
Артикул 68196
Ambient temperature -25 ... 60 °C (-13 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP54 according to EN 60529
Connection Insulation piercing technology Yellow flat cable/black flat cable M8 round plug connector in accordance with EN 61076-2-104 LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded). Matching connector: NM005-Sx1-B or similar
Mass 220 g
Switching point according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA 1 (damped) ≥ 2.0 mA
Mounting 2 clips with ∅ 8 mm drill hole
Current max. 5 A per motor
Note The flat cable routing is designed for 100 actuation cycles
Cable length 1 m
Rated operating current ≤ 35 mA
Emitted interference EN 61000-6-4:2007
Noise immunity EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Directive 2014/30/EU EN 62026-2:2013
Supply from external auxiliary voltage U
Fieldbus standard EN 62026-2:2013
LED ERR Motor fault: 2 LED yellow
LED PWR AS-Interface voltage; green LED green: voltage OK green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage U missing
Current loading capacity 500 mA , overload and short-circuit protected
Rated operating voltage 26.5 ... 31.6 V from AS-Interface
UL File Number E223772 "For use in NFPA 79 Applications only"
Number/Type 2 outputs for DC roller motors (MOT1, MOT2)
Signal delay < 1 ms (input/AS-Interface)
Input current ≤ 8 mA (limited internally)
AS-Interface specification V3.0
LED AUX ext. auxiliary voltage U ; dual LED green/red green: voltage OK red: reverse voltage
AS-Interface EN 62026-2:2013
MTBF 98 a
Slave type A/B slave
Required master specification ≥ V2.1
LED IN switching state (input); 2 LED yellow
Input EN 61131-2:2007
Profile S-7.A.E
IO code 7
ID code A
ID1 code 6
ID2 code E
D0 MOT1 fault MOT1 operation
D1 MOT2 fault MOT2 operation
D2 IN1 MOT1/MOT2 rotation direction
D3 IN2 -
LED FAULT error display; LED red red: communication error or address is 0 red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage U missing
Auxiliary voltage (output) 18 ... 30 VDC PELV
Compatible roller motors Interroll EC310, Rulmeca BL3
LED MOT Motor active; 2 yellow LEDs
Input filter 2 ms
Overload protection fuse , I t = 53.7 A s
Velocity signal 1.4 … 13 V at no-load R = 5.6 kΩ, R ≥ 35 kΩ Control via parameter P2:0
Rotation direction signal Off / ≥ (U - 1.0 V) at no-load R = 5.6 kΩ, R ≥ 5 kΩ AS-Interface data bit D2 = 0: U = Off
Motor fault Digital input NPN, U = 3.3 V, R = 52 kΩ 0 (no error) ≥ 40 µA 1 (error) ≤ 30 µA
LED FUSE Motor power supply; 2 green LEDs