Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 59195 |
MTTF | 410 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Degree of protection | IP67 |
Connection | cable piercing method flat cable yellow inputs: M12 round connector |
Housing | PBT |
Mass | 200 g |
Switching point | according to DIN EN 61131-2 (Type 2) |
Relative humidity | 85 % , noncondensing |
Altitude | ≤ 2000 m above MSL |
Mounting | Mounting plate |
Protection class | III |
Pollution degree | 3 |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
Shock and impact resistance | 30 , 11 ms in 6 spatial directions 3 shocks 10 , 16 ms in 6 spatial directions 1000 shocks |
Rated operating current | ≤ 40 mA (without sensors) / max. 240 mA |
Emitted interference | EN 61000-6-4:2007 |
Noise immunity | EN 61000-6-2:2005 EN 62026-2:2013 |
Directive 2014/30/EU | EN 62026-2:2013 |
Supply | from AS-Interface |
Fieldbus standard | EN 62026-2:2013 |
LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
Voltage | 21 ... 31 V |
Climatic conditions | For indoor use only |
Current loading capacity | ≤ 200 mA, overload and short-circuit protected |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
UL File Number | E223772 |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
Surge protection | U : Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral |
Signal delay | < 1 ms (input/AS-Interface) |
Input current | ≤ 8 mA (limited internally) |
AS-Interface specification | V3.0 |
AS-Interface | EN 62026-2:2013 |
Slave type | A/B slave |
Required master specification | ≥ V2.1 |
LED IN | switching state (input); 4 LED yellow |
0 (unattenuated) | ≤ 2 mA |
1 (attenuated) | ≥ 6 mA |
Input | EN 61131-2 |
Profile | S-0.A.0 |
IO code | 0 |
ID code | A |
ID1 code | 7 |
ID2 code | 0 |
D0 | IN1 - |
D1 | IN2 - |
D2 | IN3 - |
D3 | IN4 - |
P0 | not used |
P1 | Input filter P1 = 0 input filter on, pulse suppression ≤ 2 ms P1 = 1 input filter off (default settings) |
P2 | Synchronous mode P2 = 0 synchronous mode on P2 = 1 synchronous mode off (default settings) |
P3 | not used |
Tightening torque, cable gland | 0.4 Nm |
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of sensor supply |