  • 8-channel
  • Inputs Ex ic
  • Installation in Zone 2 or safe area
  • Dry contact or NAMUR inputs
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
  • Module can be exchanged under voltage
Параметр Значение
Общие характеристики
Артикул 58815
Ambient temperature -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20 when mounted on backplane
Connection removable front connector with spring terminal (0.14 ... 0.5 mm )
Mass approx. 90 g
Rated voltage 12 V DC , only in connection with the power supplies LB9***
Power consumption 1.55 W
Electromagnetic compatibility NE 21
Relative humidity 95 % non-condensing
Current 12 mA
Connection 2 volt-free contact
Marking II 3 G Ex nA [ic] IIC T4 Gc
Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Dimensions 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
IECEx approval EXA 13.0003X
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Approved for Ex nA [ic] IIC T4 Gc
System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Power 30 mW (linear characteristic)
LED indication Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-8) red: line fault (lead breakage or short circuit) , yellow: signal (per channel)
Directive 2014/30/EU EN 61326-1
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Certificate EXA 13 ATEX 0037X
Directive 2014/34/EU EN 60079-0:2011 EN 60079-11:2011 EN 60079-15:2010
Power dissipation 1.55 W
Voltage 10 V
Connection 3 Usage without connection to areas where there is a risk of explosion: active signals, mechanical contacts, NAMUR proximity switches, 2-wire sensors If the device has been operated in general electrical systems that are connected to areas where there is a risk of explosion, the device cannot then be used in electrical systems that connected to areas where there is a risk of explosion. Usage with connection to areas where there is a risk of explosion: mechanical contacts, NAMUR proximity switches
Line fault detection can be switched on/off for each channel via configuration tool , active signals (24 V, 5 V) without line fault detection
Minimum pulse duration 15 ms
ATEX approval EXA 13 ATEX 0037X
Rated values acc. to EN 60947-5-6 (NAMUR)
Switching point/switching hysteresis 1.2 ... 2.1 mA / ± 0.2 mA
Open-circuit < 0.35 mA
Short-circuit < 360 Ω
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Internal resistor 1 kΩ
Interface manufacturer-specific bus to standard com unit
Coding optional mechanical coding via front socket
Occupied slots 1
Number of channels 8
Environmental test EN 60068-2-14
Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Lloyd Register 15/20021
Bureau Veritas Marine 22449/B0 BV
Digital signals (active) Use in safe area: configurable 24 V 5 V
Switching point ON > 8 V > 2.7 V
Switching point OFF < 3 V < 2.3 V

Техподдержка