  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • HART communication via PROFIBUS DP V1 or service bus
  • Configuration via FDT 1.2 DTM
  • Configuration in run (CiR) for any PCS
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage
Параметр Значение
Общие характеристики
Артикул 69250
UL approval E106378
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20 (module) , mounted on backplane
Connection via backplane
Mass approx. 120 g
Rated voltage 5 V DC , only in connection with the power supplies LB9***
Power consumption 1.8 W
Electromagnetic compatibility NE 21
Relative humidity 95 % non-condensing
Marking II 3 G Ex nA IIC T4 Gc
Protocol PROFIBUS DP/DP V1 read/write services
Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Dimensions 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
IECEx approval BVS 09.0037X
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
EAC approval Russia: RU C-IT.MIII06.B.00129
Approved for Ex nA IIC T4 Gc
System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
LED indication LED P: (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active LED 1: (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED 2: (status fieldbus): flashing = PROFIBUS receive channel active LED 3: (status service bus): flashing = service bus receive channel active LED 4: (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation LED 5: (status fieldbus): flashing = PROFIBUS response channel active LED 6: (status service bus): flashing = service bus response channel active
Directive 2014/30/EU EN 61326-1
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Certificate PF 08 CERT 1234 X
Directive 2014/34/EU EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010
Power dissipation 1.8 W
Control drawing 116-0321
Fieldbus type PROFIBUS DP/DP-V1
Fieldbus standard IEC 61158-2
ATEX approval PF 08 CERT 1234 X
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Baud rate up to 1.5 MBit/s
HART communication via PROFIBUS or service bus
Environmental test EN 60068-2-14
Lloyd Register 15/20021
Bureau Veritas Marine 22449/B0 BV
American Bureau of Shipping T1450280/UN
DNV GL Marine TAA0000034
Number of stations per bus line max. 125 (PROFIBUS), max. 119 (service bus)
Cyclic process data 240 bytes input and (simultaneously) 240 bytes output
Number of stations per bus segment max. 31 (RS-485 standard)
Number of repeaters between Master and Slave max. 3
Supported I/O modules all LB remote I/O modules
Configuration (240 bytes I/O) Standard: 80 analog, 184 digital Universal 2I2O: 48 analog, 184 digital Universal 4I4O: 60 analog, 120 digital
Bus length max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd)
Addressing via configuration software
PROFIBUS address 0 ... 126 (factory standard setting: 126)
GSE file CGV61710.gsd/gse
Redundancy via backplane