Пт-Пн: 9:00 - 18:00

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Цены носят информационный характер и не являются публичной офертой. Точную цену и срок поставки подтвердит менеджер при оформлении заявки
Доставка в любой регион России транспортной
компанией на Ваш выбор
| Параметр | Значение |
| Общие характеристики | |
| Артикул | 33551 |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm ) or screw terminals (0.08 ... 1.5 mm ) |
| Mass | approx. 750 g |
| Rated voltage | 12 V DC , only in connection with the power supplies FB92** |
| Power consumption | 0.75 W |
| Electromagnetic compatibility | NE 21 |
| Relative humidity | 95 % non-condensing |
| Current | 71 mA |
| Measurement range | -65 ... 75 mV with LFD , -75 ... 75 mV without LFD |
| Linearity error | 0.1 % |
| Marking | II 2(1) G Ex d [ia Ga] IIC Gb II (1) D [Ex ia Da] IIIC |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
| EU-type examination certificate | PTB 97 ATEX 1074 U |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| EAC approval | Russia: RU C-IT.MIII06.B.00129 |
| System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
| Power | 62 mW (trapezoid characteristic curve) |
| LED indication | LED green: supply LED red: line fault, collective alarm , flashing: communication error |
| Directive 2014/30/EU | EN 61326-1 |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Directive 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 |
| Power dissipation | 0.75 W |
| Voltage | 1 V |
| Line fault detection | can be switched on/off for each channel via configuration tool , |
| ATEX approval | PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U |
| Open-circuit | > 1 kΩ |
| Influence of ambient temperature | max. 0,1 %/10 K |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Compensation (reference junction CJC) | internal cold junction compensation or external cold junction |
| Interface | manufacturer-specific bus to standard com unit |
| Coding | optional mechanical coding via front socket |
| Occupied slots | 2 |
| Number of channels | 4 |
| Field device [2] | Thermocouple |
| Field device [4] | mV source |
| Conversion time | max. 300 ms (4 channels) without LFD max. 600 ms (4-channel) with LFD |
| Environmental test | EN 60068-2-14 |
| Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Lloyd Register | 15/20021 |
| Bureau Veritas Marine | 22449/B0 BV |
| American Bureau of Shipping | T1450280/UN |
| DNV GL Marine | TAA0000034 |
| Smallest span | 5 mV for 0.1 % accuracy |
| Sensor | thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources |
| Input/input | functional insulation acc. to IEC 60664-1:2007, rated insulation voltage 50 V, testing voltage 500 V |