Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Thermocouple Converter FB5202B

Thermocouple Converter FB5202B
Thermocouple Converter FB5202B

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 33548
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 1-channel
  • Input Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Converter for thermocouples and mV-signals
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
Параметр Значение
Общие характеристики
Артикул 33548
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20 (module) , a separate housing is required acc. to the system description
Connection removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm ) or screw terminals (0.08 ... 1.5 mm )
Mass approx. 350 g
Rated voltage 12 V DC , only in connection with the power supplies FB92**
Power consumption 0.45 W
Electromagnetic compatibility NE 21
Relative humidity 95 % non-condensing
Current 43 mA
Measurement range -75 ... mV ... 75 mV
Linearity error 0.1 %
Marking II 2(1) G Ex d [ia Ga] IIC Gb II (1) D [Ex ia Da] IIIC
Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Dimensions 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch)
EU-type examination certificate PTB 97 ATEX 1074 U
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
EAC approval Russia: RU C-IT.MIII06.B.00129
System information The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Power 67 mW (trapezoid characteristic curve)
LED indication LED green: supply LED red: line fault
Directive 2014/30/EU EN 61326-1
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Directive 2014/34/EU EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006
Power dissipation 0.45 W
Voltage 1.8 V
Line fault detection can be switched on/off for each channel via configuration tool ,
ATEX approval PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
Open-circuit > 1 kΩ
Influence of ambient temperature max. 0,1 %/10 K
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Compensation (reference junction CJC) internal cold junction compensation or external cold junction
Interface manufacturer-specific bus to standard com unit
Coding optional mechanical coding via front socket
Occupied slots 1
Number of channels 1
Field device [2] Thermocouple
Field device [4] mV source
Conversion time internal cold junction: max. 120 ms without LFD max. 240 ms with LFD external cold junction: max. 20 ms without LFD max. 80 ms with LFD
Environmental test EN 60068-2-14
Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Lloyd Register 15/20021
Bureau Veritas Marine 22449/B0 BV
American Bureau of Shipping T1450280/UN
DNV GL Marine TAA0000034
Smallest span 5 mV for 0.1 % accuracy
Sensor thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено