Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Switch Amplifier KCD2-SR-2.SP

Switch Amplifier KCD2-SR-2.SP
Switch Amplifier KCD2-SR-2.SP

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 52668
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact output
  • Line fault detection (LFD)
  • Housing width 12.5 mm
  • Connection via spring terminals with push-in connection technology
  • Up to SIL 2 acc. to IEC 61508
Параметр Значение
Общие характеристики
Артикул 52668
Control elements DIP-switch
Ripple ≤ 10 %
Switching frequency ≤ 10 Hz
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Degree of protection IP20
Connection spring terminals
Mass approx. 100 g
Rated voltage 19 ... 30 V DC
Power consumption ≤ 600 mW
Electromagnetic compatibility NE 21:2006
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Dimensions 12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mechanical life 10 switching cycles
Labeling space for labeling at the front
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Rated current ≤ 30 mA
Output I signal ; relay
Contact loading 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 30 V DC/2 A resistive load
Output II signal ; relay
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Safety Integrity Level (SIL) SIL 2
Display elements LEDs
Optional accessories - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-GY(-UPR-03)
Power dissipation ≤ 600 mW
Energized/De-energized delay ≤ 20 ms / ≤ 20 ms
Configuration via DIP switches
Directive 2014/35/EU EN 61010-1:2010
Connection side control side
Input/Output reinforced insulation acc. to EN 50178, rated insulation voltage 300 V
Output/Output reinforced insulation acc. to EN 50178, rated insulation voltage 300 V
Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Signal type Digital Input
Rated values acc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit current approx. 10 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Minimum switch current 2 mA / 24 V DC
Input/power supply reinforced insulation acc. to EN 50178, rated insulation voltage 300 V
Output/power supply reinforced insulation acc. to EN 50178, rated insulation voltage 300 V
Input/input Basic insulation according to EN 50178, rated insulation voltage 300 V
Safety note If load voltage > 50 V, de-energize before removing the terminals.
Pulse/Pause ratio min. 20 ms / min. 20 ms