Параметр | Значение |
Общие характеристики | |
Артикул | 4123 |
Материал | float: PP (Polypropylene) cable: - PVC version: PVC cable, highly flexible (2 x 0.75 mm ) - PUR version: PUR cable, highly flexible (2 x 0.50 mm ) - CSM/CM version: CSM/CM cable (chlorinated polyethylene, (2 x 0.75 mm )) |
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) |
Degree of protection | IP68 |
Rated voltage | 8.2 V ± 2 V |
Switching point | switch angle, measured against the horizontal: - upper switch point +15° ±5° - lower switch point -15° ±5° |
Altitude | ≤ 2000 m above MSL |
Marking | II 2G Ex ia IIB T5 Gb |
Reverse polarity protection | yes |
EU-type examination certificate | TÜV 99 ATEX 1407 |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Directive 2014/30/EU | EN 60947-5-2:2007+A1:2012 |
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 |
Equipment architecture | A measuring system consists of a float switch LFL1-**-N and a transformer isolated barrier, e. g. KFD2-SR2-Ex1.W. |
Current consumption | < 1.0 mA unswitched (de-energized at the bottom), > 2.2 mA switched (floated up at the top) |
Description | Proximity switch with operation ball |
Process pressure (static pressure) | sleeve design: ≤ 3 bar at 20 °C (68 °F) ball design: ≤ 2 bar at 20 °C (68 °F) |
Density | sleeve design: ≥ 0.8 g/cm ball design: ≥ 0.6 g/cm |
Installation instructions | range of application and minimum length between mounting and float: - PVC version: ≥ 50 mm (2 inch), preferred for water - PUR version: ≥ 100 mm (4 inch), preferred for fuels, heating oils, oily fluids - CSM/CM version: ≥ 100 mm (4 inch), preferred for many acids and lyes mounting: - The float switch is mounted either from sidewards through a cable gland ≥ G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal. |