Параметр | Значение |
Общие характеристики | |
Артикул | 72078 |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) vertically mounted , -40 ... 70 °C (-40 ... 158 °F) horizontally mounted |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP20 |
Mass | 250 g |
Rated voltage | 19.2 ... 35 V SELV/PELV |
Electromagnetic compatibility | NE 21:2011 |
Relative humidity | < 95 % non-condensing |
Mounting | motherboard mounting |
Housing width | 40 mm |
Housing depth | 128 mm |
Transfer rate | 100 MBit/s |
Housing height | 106 mm |
Pollution degree | max. 2, according to IEC 60664 |
Protocol | PROFINET |
Vibration resistance | 1 g , 10 ... 150 Hz |
Housing material | Polycarbonate |
IECEx approval | IECEx TUR 16.0007X |
Group, category, type of protection, temperature class | II 3 G Ex ec IIC T4 Gc |
LED red | yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available |
Approved for | Ex ec IIC T4 Gc |
Rated current | typ. 135 mA |
Directive 2014/30/EU | EN 61326-1:2013 |
Shock resistance | 15 g 11 ms |
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 |
Power dissipation | approx. 3.5 W |
Design / Mounting | Motherboard based |
Number of segments | 4 |
Fieldbus type | PROFIBUS PA |
LED Seg 1...4 | red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Marine approval | pending |
Fieldbus standard | IEC 61158-2 |
LED ERR | red 2 Hz flashing: Ethernet error |
LED PWR | green: Power on |
Statement of conformity | TÜV 15 ATEX 7735 X |
All circuits/FE | functional insulation acc. to IEC 61010, rated insulation voltage 50 V |
Redundancy | Ring (MRP) , System S2 |
PROFIBUS DP/Supply | functional insulation acc. to IEC 61010, rated insulation voltage 50 V |
Ethernet/Supply | functional insulation acc. to IEC 61010, rated insulation voltage 50 V |
Number of devices per segment | max. 32 |
Number of ports | 2 |
Ethernet Interface | Connector , 2x RJ45 |
LED ETH1 LINK 2 | green: link status |
LED ETH1 ACT | yellow: activity status |
LED ETH2 LINK | green: link status |
LED ETH2 ACT | yellow: activity status |
LED DP/ERR | red 2 Hz flashing: DP error ; red: Hardware error |
CH/PROFIBUS DP | functional insulation acc. to IEC 61010, rated insulation voltage 50 V |
CH/CH | functional insulation acc. to IEC 61010, rated insulation voltage 50 V |
CH/Ethernet | functional insulation acc. to IEC 61010, rated insulation voltage 50 V |