Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

WirelessHART Adapter WHA-ADP2-F8B2-0-A0-Z1-Ex1

WirelessHART Adapter WHA-ADP2-F8B2-0-A0-Z1-Ex1
WirelessHART Adapter WHA-ADP2-F8B2-0-A0-Z1-Ex1

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 85850
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 1-channel
  • Installation in Zone 1, Zone 21, and Class I Div. 1
  • WirelessHART Adapter
  • Battery operated
  • Also supplies field device
  • Input 2-wire HART transmitters and 2-wire HART current sources
  • Output WirelessHART wireless interface
  • Direct mounting on HART or 4 mA ... 20 mA field device
  • Rotatable antenna
Параметр Значение
Общие характеристики
Артикул 85850
Материал Aluminum
Ambient temperature -40 ... 60 °C (-40 ... 140 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Degree of protection IP66
Connection terminals 1, 2, 3, 4, 5, 6 multiple wirings available , depending on operating mode
Mass approx. 1000 g
Rated voltage 7.2 V DC , battery operated
Parameter assignment - wireless transmit power: configurable to 0 dBm or 10 dBm (EIRP) - device variables mapping - publishing of up to ten burst messages in a wireless network, period and trigger mode selectable - notification of up to five events from adapter and/or connected device(s) in a wireless network - scaling and linearization of 4 ... 20 mA signal of connected analog device - tuning of supply parameters for the connected device - locking/unlocking of device parameterization
Mounting mounting on field device , panel or pole mounting
Current 4 ... 20 mA
Transfer rate 1200 Bit/s
Marking II 2G Ex ia IIC T4/T3 Gb II 2D Ex tb [ia] IIIC T70°C Db
Protocol HART 7.3, backward compatible
Vibration resistance 20 ... 2000 Hz, 0,01 g /Hz
Dimensions 92 x 89.5 x 92.8 mm (without cable glands and antenna)
EU-type examination certificate BVS 17 ATEX E 029
Designation battery W-BAT-B2-Li mandatory for use in connection with hazardous areas (order separately) mounting set W-ACC-F8MK threads (NPT 1/2", NPT 3/4", G 1/2, M20)
Directive 2014/30/EU EN 61326-1:2013, CLASS A
Directive 2011/65/EU (RoHS) EN 50581:2012
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2014
Supply loop power for field devices voltage 8 ... 23 V DC, adjustable in steps of 0.1 V
Accuracy current input: 0.125 % of measuring range
Output rated operating current 4 ... 20 mA
Control drawing 116-0435
Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 test setup and execution acc. to EN 60068-2-60
IECEx certificate IECEX BVS 17.0023
Directive 2014/53/EU EN 300328 V2.1.1:2017 , EN 301489-17 V3.1.1:2017 , EN 301489-1 V2.1.1:2017
Influence of ambient temperature current input: 5 µA/K
Suitable field devices usable for: - one point-to-point connection with a HART field device, or - one point-to-point connection with a 4 ... 20 mA field device, or - up to four externally powered HART field devices operating in multidrop mode
Number of devices - one passive 4 ... 20 mA/HART field device - up to 4 HART field devices in multidrop mode
Parameters primary/secondary master, preambles, retries and short address scan ranges
Output variables PV: loop current SV, TV, QV:configurable according to user requirement - adapter: temperature, battery voltage, energy consumed and estimated battery life-time - 4 ... 20 mA device: scaled or linearized process value - HART device: up to four process variables
Radio and telecommunication terminal equipment The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning.
FCC CFR47 Part 15 B and C ANSI C63.4-2003

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено