Switch Amplifier KFD2-ST2-Ex1.LB

Switch Amplifier KFD2-ST2-Ex1.LB
Switch Amplifier KFD2-ST2-Ex1.LB

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 27749
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Active transistor output
  • Active fault output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508
Параметр Значение
Общие характеристики
Артикул 27749
Control elements DIP-switch
Ripple ≤ 10 %
Switching frequency ≤ 5 kHz
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Rated voltage 20 ... 30 V DC
Electromagnetic compatibility NE 21:2004
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Current 13 mA
Marking II 3G Ex nA II T4
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Labeling space for labeling at the front
EU-type examination certificate PTB 00 ATEX 2035
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Power 34 mW (linear characteristic)
Rated current ≤ 50 mA
Output I signal , electronic output, active
Output II signal or error message , electronic output, active
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Certificate TÜV 99 ATEX 1499 X
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000
Safety Integrity Level (SIL) SIL 2
Display elements LEDs
Optional accessories - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-BU(-UPR-03)
Configuration via DIP switches
Control drawing 116-0047
Galvanic isolation IEC 62103:2003
IECEx certificate IECEx PTB 05.0011
IECEx marking [Ex ia] IIC , [Ex ia] I , [Ex ia] IIIC
Voltage 10.5 V
Maximum safe voltage 40 V DC (Attention! The rated voltage can be lower.)
Signal level 1-signal: (L+) - 3.5 V (100 mA, short-circuit protected) 0-signal: switched off (off-state current ≤ 10 µA)
Connection side control side
Input Ex ia IIC, Ex ia IIIC
Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Output/Output not available , common pole terminal 14+
Line fault detection breakage I ≤ 0.1 mA , short-circuit I > 6 mA
Signal type Digital Input
Rated values acc. to EN 60947-5-6 (NAMUR), see system description for electrical data
Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Output/power supply not available , common pole terminal 14+
Collective error message Power Rail