| Параметр | Значение |
| Общие характеристики | |
| Артикул | 11892 |
| MTTF | 190 a |
| Mission Time (T | 10 a |
| Diagnostic Coverage (DC) | 0 % |
| Ripple | ≤ 10 % at 30 V DC |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -30 ... 80 °C (-22 ... 176 °F) |
| Degree of protection | IP67 |
| Connection | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M6 earthing screw RS 232: M12 plug connection |
| Housing | powder coated aluminum |
| Mass | approx. 1000 g |
| Power consumption | 2.5 W Without read/write heads |
| Transfer rate | 1200; 2400; 4800; 9600; 19200; 38400 Bit/s |
| Protocol | ASCII |
| Installation | snap-on to 35 mm standard rail or screw fixing |
| Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Physical | RS 232 |
| Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 V |
| Climatic conditions | air humidity max. 96 % Salt spray resistant to EN 60068-2-52 |
| Current consumption | ≤ 2 A incl. read/write heads |
| Rated operating voltage | 20 ... 30 V DC , PELV |
| UL File Number | E87056 |
| LED PWR/ERR | green: power on red: Hardware fault |
| Button | 4 keys: ESC, up, down and return |
| Number of read/write heads | max. 4 alternative 2 read/write heads and 2 trigger sensors |
| LC display | two-line multi-function display with 12 characters per line configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands |
| LEDs 1, 2, 3, 4 | Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed |
| LED UL | green: Interface Power ON/OK |
| LED TxD | green: flashes in rhythm with the transmitted data |