Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Inductive sensor NJ15+U4+N 10234

Inductive sensor NJ15+U4+N

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 10234
Под заказ
Запрос цены

Цены носят информационный характер и не являются публичной офертой. Точную цену и срок поставки подтвердит менеджер при оформлении заявки

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Comfort series
  • 15 mm flush
Параметр Значение
Общие характеристики
Артикул 10234
Switching frequency 0 ... 120 Hz
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Degree of protection IP68
Note Tightening torque: 1.8 Nm (housing)
Output type 2-wire
Switching function Normally closed (NC)
Rated operating distance 15 mm
Installation flush
Assured operating distance 0 ... 12.15 mm
CSA approval cCSAus Listed, General Purpose
Connection type screw terminals
Housing material PBT/metal
Sensing face PBT
Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
Core cross-section up to 2.5 mm
CE marking [*PD-Z02585A*]
Control drawing 116-0451
Nominal voltage 8.2 V (R approx. 1 kΩ)
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
Appropriate type NJ 15+U.+N...
Effective internal capacitance max. 140 nF ; a cable length of 10 m is considered.
Effective internal inductance max. 130 µH ; a cable length of 10 m is considered.
Use in the hazardous area see instruction manuals
Category 1G; 2G; 1D
Measuring plate not detected min. 3 mA
Measuring plate detected ≤ 1 mA
Information for connection A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Minimum core cross-section without wire end ferrule 0.5 mm , with connector sleeves 0.34 mm
Maximum core cross-section without wire end ferrule 2.5 mm , with connector sleeves 1.5 mm
Highest permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
Reduction factor r 0.85
Ordinary Location E87056
Hazardous Location E501628

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Пользовательского соглашения.

Спасибо!