Пт-Пн: 9:00 - 18:00

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Цены носят информационный характер и не являются публичной офертой. Точную цену и срок поставки подтвердит менеджер при оформлении заявки
Доставка в любой регион России транспортной
компанией на Ваш выбор
| Параметр | Значение |
| Общие характеристики | |
| Артикул | 2866 |
| Slot width | 10 mm |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 1000 Hz |
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Degree of protection | IP67 |
| Bending radius | > 10 x cable diameter |
| Output type | 2-wire |
| Type of protection | intrinsic safety |
| Switching function | Normally closed (NC) |
| CSA approval | cCSAus Listed, General Purpose |
| Connection type | cable PVC , 5 m |
| Housing material | PBT |
| Standards | IEC 60079-0:2011 , IEC 60079-11:2011 |
| Core cross-section | 0.75 mm |
| CE marking | [*PD-Z02585A*] |
| Control drawing | 116-0453 |
| IECEx certificate | IECEx PTB 11.0091X |
| IECEx marking | Ex ia I Mb |
| Nominal voltage | 8.2 V (R approx. 1 kΩ) |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| ATEX marking | II 1D Ex ia IIIC T135°C Da |
| Appropriate type | SJ10-N... |
| Effective internal capacitance | max. 50 nF A cable length of 10 m is considered. |
| Effective internal inductance | max. 1000 µH A cable length of 10 m is considered. |
| Use in the hazardous area | see instruction manuals |
| Measuring plate not detected | ≥ 3 mA at nominal voltage |
| Measuring plate detected | ≤ 1 mA at nominal voltage |
| Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at U = 16 V , I = 25 mA , P = 34 mW : 100 °C (212 °F) at U = 16 V , I = 25 mA , P = 64 mW : 100 °C (212 °F) at U = 16 V , I = 52 mA , P = 169 mW : 82 °C (179.6 °F) at U = 16 V , I = 76 mA , P = 242 mW : 63 °C (145.4 °F) |
| Equipment protection level | Ga , Gb , Da , Mb |
| ATEX certificate | PTB 99 ATEX 2219 X |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| for ATEX | at U = 16 V , I = 25 mA , P = 34 mW , T6 : 55 °C (131 °F) T5 : 67 °C (152.6 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) at U = 16 V , I = 25 mA , P = 64 mW , T6 : 48 °C (118.4 °F) T5 : 60 °C (140 °F) T4 : 88 °C (190.4 °F) T3 : 88 °C (190.4 °F) T2 : 88 °C (190.4 °F) T1 : 88 °C (190.4 °F) at U = 16 V , I = 52 mA , P = 169 mW , T6 : 25 °C (77 °F) T5 : 37 °C (98.6 °F) T4 : 65 °C (149 °F) T3 : 65 °C (149 °F) T2 : 65 °C (149 °F) T1 : 65 °C (149 °F) at U = 16 V , I = 76 mA , P = 242 mW , T6 : 9 °C (48.2 °F) T5 : 21 °C (69.8 °F) T4 : 49 °C (120.2 °F) T3 : 49 °C (120.2 °F) T2 : 49 °C (120.2 °F) T1 : 49 °C (120.2 °F) |
| for IECEx | at U = 16 V , I = 25 mA , P = 34 mW , T6 : 72 °C (161.6 °F) T5 : 87 °C (188.6 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U = 16 V , I = 25 mA , P = 64 mW , T6 : 66 °C (150.8 °F) T5 : 81 °C (177.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U = 16 V , I = 52 mA , P = 169 mW , T6 : 42 °C (107.6 °F) T5 : 57 °C (134.6 °F) T4 : 82 °C (179.6 °F) T3 : 82 °C (179.6 °F) T2 : 82 °C (179.6 °F) T1 : 82 °C (179.6 °F) at U = 16 V , I = 76 mA , P = 242 mW , T6 : 26 °C (78.8 °F) T5 : 41 °C (105.8 °F) T4 : 63 °C (145.4 °F) T3 : 63 °C (145.4 °F) T2 : 63 °C (145.4 °F) T1 : 63 °C (145.4 °F) |
| Depth of immersion (lateral) | 13.5 ... 16.5 typ. 15 mm |