Digital Output FB6210BR

Digital Output FB6210BR
Digital Output FB6210BR

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 89629
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 4-channel
  • Outputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Line fault detection (LFD)
  • Positive or negative logic selectable
  • Simulation mode for service operations (forcing)
  • Permanently self-monitoring
  • Output with watchdog
Параметр Значение
Общие характеристики
Артикул 89629
Response time 10 ms (depending on bus cycle time)
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20 (module) , a separate housing is required acc. to the system description
Connection removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm ) or screw terminals (0.08 ... 1.5 mm )
Mass approx. 750 g
Rated voltage 12 V DC , only in connection with the power supplies FB92**
Power consumption 0.15 W
Electromagnetic compatibility NE 21
Relative humidity 95 % non-condensing
Current 90.4 mA
Marking II 2(1) G Ex d [ia Ga] IIC Gb II (1) D [Ex ia Da] IIIC
Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Dimensions 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)
EU-type examination certificate PTB 97 ATEX 1074 U
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
EAC approval Russia: RU C-IT.MIII06.B.00129
System information The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Power 629 mW
LED indication LED green: supply LED red: line fault , red flashing: communication error
Directive 2014/30/EU EN 61326-1
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Directive 2014/34/EU EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006
Power dissipation 3 W
Voltage 27.8 V
Reaction time 10 s
Current limit 37 mA
Line fault detection can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms)
Open loop voltage 24.5 V
ATEX approval PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
Open-circuit > 15 kΩ
Short-circuit < 100 Ω
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Internal resistor max. 370 Ω
Interface manufacturer-specific bus to standard com unit
Coding optional mechanical coding via front socket
Internal capacitance 2.5 nF
Internal inductance 0 mH
Occupied slots 2
Number of channels 4
Field device Solenoid Valve
Field device [2] audible alarm
Field device [3] visual alarm
Environmental test EN 60068-2-14
Lloyd Register 15/20021
Bureau Veritas Marine 22449/B0 BV
American Bureau of Shipping T1450280/UN
DNV GL Marine TAA0000034
Watchdog within 0.5 s the device goes in safe state, e.g. after loss of communication
Output/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Input voltage range 18.5 ... 32 V DC (SELV/PELV) booster voltage