Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

6500 series vent EPV-6500-*-*

6500 series vent EPV-6500-*-*
6500 series vent EPV-6500-*-*

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 74235
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • A selection of vents for specific applications
  • Intrinsically safe operation
  • Continuous flow vents for precise flow rates for dilution applications
  • Continuous flow outputs for dilution, purging, and pressurization
  • Low leakage rate vents for air or inert gas conversation
  • High flow rate vents for fast, large enclosure systems
  • Universal mounting in any orientation including most of the unit inside the enclosure
  • Maximum enclosure size 12.75 cu.meters (450 cu.ft.)
  • ATEX/IECEx Zone 1/21 certified for Ex pyb and Ex pxb
  • Up to SIL 2 acc. to IEC 61508
Параметр Значение
Общие характеристики
Артикул 74235
Ambient temperature -20 ... 70 °C (-4 ... 158 °F)
Storage temperature -40 ... 70 °C (-40 ... 158 °F)
Degree of protection IP66
Connection M12 connector, 4-pin, cable length 5 meters (provided)
Housing EPV-6500-AA... body: 6000 series aluminum anodized cap: 5000 series aluminum anodized EPV-6500-SS... body: 6000 series Aluminum anodized cap: 316L stainless steel
Mass approx. 1.4 kg (3.1 lb)
Relative humidity 5 ... 90 %, non-condensing
Mounting 1 ½" NPT knockout (50.8mm (2") hole) with seal nut included
Vibration resistance 5 ... 100 Hz , 1 g, 12 m/s , all axes
Dimensions 127 x 146 x 83 mm (5.0" x 5.8" x 3.3")
Installation - any orientation to enclosure - not gravity dependent - internal and external mounting possible
EU-type examination certificate ATEX UL / DEMKO 15 ATEX 1622X
IECEx approval IECEx UL / DEMKO 15.0147X
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Cable length max. 60 meters at 50 pf/ft and 0.2 µH/ft
Series 6500
Number of volume exchanges 5 to 19
Hazardous environment gas, dust, gas and dust
Signal BUS back to the 6500 control unit
LED indication POWER: green
Protective gas supply instrument grade air or inert gas
Safe pressure Gas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa) Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa) Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Purge flow rate See graphs Readout on display is in increments of 28 l/min (1 scfm). Minimum and maximum reading depends on type of vent and supply pressure. EPV-6500-*-07, 08 will readout continuous flow.
Purge flow and enclosure pressure rate See graphs Readout on display is in increments of 28 l/min (1 scfm). Minimum and maximum reading depends on type of vent and supply pressure. EPV-6500-*-07, 08 will readout continuous flow.
Flow rate for leakage compensation EPV-6500....-01: 593 l/hr (21 scfh) @ .63mbar (.25"wc) 1640 l/hr (58 scfh) @ 1.9mbar (0.75"wc) EPV-6500....-03: 395 l/hr (14 scfh) @ .63mbar (.25"wc) 961 l/hr (34 scfh) @ 1.9mbar (0.75"wc) EPV-6500....-05: 260 l/hr (9.2 scfh) @ .63mbar (.25"wc) 622 l/hr (22 scfh) @ 1.9mbar (0.75"wc) EPV-6500....-07: n/a EPV-6500....-08: n/a
Breaking pressure EPV-6500-...-01: 2.0 mbar (0.8" wc) EPV-6500-...-03: 3.5 mbar (1.4" wc) EPV-6500-...-05: 3.8 mbar (1.5" wc) EPV-6500-...-07: n/a EPV-6500-...-08: n/a
Impact resistance 30 g, 11 ms, all axes
Spark arrestor 304 (UNS S30400) stainless steel
Directive 94/9/EC EN 60079-0:2012 , EN 60079-2:2014 , EN 60079-11:2011
Maximum pressure depends on the integrity of the enclosure (strength) max. vent pressure: 25'' wc (635 mm wc) (62 mbar / 6200 pa) vent pressure range: 0 to 9.9" wc (0 to 25 mbar)
Shock resistance EN 60068-2
Safety Integrity Level (SIL) SIL 2

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено