Параметр | Значение |
Общие характеристики | |
Артикул | 17200 |
Материал | F14 housing: polyester PBT-FR F34 housing F34: aluminum Probe: PPS GF40 probe rope: PE-HD probe rope seal: VMQ |
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) (Dust-Ex version) |
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) |
Degree of protection | IP66, NEMA 4 |
Connection | gland M20 thread G1/2, NPT1/2 |
Rated voltage | electrical connection E5: 10.8 ... 45 V DC, short-term pulse on 55 V DC electrical connection WA: 20 ... 235 V AC, 50/60 Hz or 20 ... 55 V DC |
Electromagnetic compatibility | NE 21 |
Construction type | device rope probe |
Operating mode | MAX = maximum safety: The device switches if the probe is covered or if the supply voltage is disconnected in a safety-oriented manner (signal on alarm). example application: overspill protection MIN = minimum safety: The device switches if the probe is uncovered or if the supply voltage is disconnected in a safetyoriented manner (signal on alarm). example application: dry-running protection |
Measurement range | dielectric constant ≥ 1.6 |
Output signal | connection E5: switching PNP, I = 200 mA - overload and short circuit protection - residual voltage at transistor at I < 2.9 V connection WA: contact change-over, potential-free - U = 253 V - I = 4 A (AC) - P = 1000 VA, cos φ = 1, P = 500 VA, cos φ > 0.7 |
Reference operating conditions | vessel type: plastic vessel, ambient temperature: 73 °F (23 °C, 296 K), medium temperature: 73 °F (23 °C, 296 K) medium pressure p : 0 bar, medium: dielectric constant = 2.6, conductivity: < 1 µS sensitivity setting: C |
Vibration resistance | a(RMS) = 50 m/s , ASD = 1.25 (m/s ) /Hz, f = 5 to 2000 Hz, t = 3 x 2 h |
Dimensions | max. ∅94 mm (3.7 inch), length 140 mm (5.5 inch) + L L = 500 ... 6000 mm (19.7 ... 236 inch) |
Process connection | thread R1-1/2 acc. to EN 10226, BSPT thread NPT1-1/2 to ANSI B 1.20.1 |
Hysteresis | vertical 5 mm (0.2 inch) |
Measuring method | A metal plate at the end of the probe, within the insulation, and the surroundings (e. g. the silo walls) combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the LCL switches. |
EU-type examination certificate | see instruction manuals (SI) |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Switch-on delay | correct switching after max. 2 s |
Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 |
Shock resistance | device with F34 housing: 7 J |
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009 |
Equipment architecture | The measuring system consists of: - the device - a supply point - the connected control systems, switching units, signalling systems (e. g. lamps, horns, PCS, PLC, etc.) |
Optional accessories | LCL-Z10 cover with sight glass for F14 housing LCL-Z14 rope shortening set |
Directive 2014/35/EU | EN 61010-1:2010 |
Current consumption | electrical connection E5: max. 30 mA, reverse-polarity-proof electrical connection WA: max. 130 mA |
Surge protection | overvoltage category III |
Installation position | vertically down |
Mounting location | The capacitive limit switch can be installed in silos made of different materials (e. g. metal, plastic, concrete). |
Measured variable | limit level (limit value) |
Climate class | EN 60068, part 2-38 (test Z/AD) |
Influence of medium temperature | depending on the filling material |
Switching time | approx. 0.8 s when covering and uncovering the sensor |
State of aggregation | solids |
Solid contents | ≤ ∅ 30 mm |
Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI) |
Process temperature | -40 ... 80 °C (-40 ... 176 °F) |
Long-term drift | vertical 6 mm (0.24 inch) |
Signal on alarm | connection E5: < 100 µA connection WA: relay de-energized |
Medium pressure limits | -1 ... 6 bar |
Bulk density | ≤ 200 g/l |