Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Capacitive limit switch LCL2

Capacitive limit switch LCL2
Capacitive limit switch LCL2

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 17200
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Limit switch for bulk solids
  • Device with rope probe
  • Rope probe can be shortened for optimum matching to the measuring point
  • Complete unit consisting of the probe and electronic insert
  • Integrated active build-up compensation: exact switch point, even with strong build-up
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
Параметр Значение
Общие характеристики
Артикул 17200
Материал F14 housing: polyester PBT-FR F34 housing F34: aluminum Probe: PPS GF40 probe rope: PE-HD probe rope seal: VMQ
Ambient temperature -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) (Dust-Ex version)
Storage temperature -40 ... 80 °C (-40 ... 176 °F)
Degree of protection IP66, NEMA 4
Connection gland M20 thread G1/2, NPT1/2
Rated voltage electrical connection E5: 10.8 ... 45 V DC, short-term pulse on 55 V DC electrical connection WA: 20 ... 235 V AC, 50/60 Hz or 20 ... 55 V DC
Electromagnetic compatibility NE 21
Construction type device rope probe
Operating mode MAX = maximum safety: The device switches if the probe is covered or if the supply voltage is disconnected in a safety-oriented manner (signal on alarm). example application: overspill protection MIN = minimum safety: The device switches if the probe is uncovered or if the supply voltage is disconnected in a safetyoriented manner (signal on alarm). example application: dry-running protection
Measurement range dielectric constant ≥ 1.6
Output signal connection E5: switching PNP, I = 200 mA - overload and short circuit protection - residual voltage at transistor at I < 2.9 V connection WA: contact change-over, potential-free - U = 253 V - I = 4 A (AC) - P = 1000 VA, cos φ = 1, P = 500 VA, cos φ > 0.7
Reference operating conditions vessel type: plastic vessel, ambient temperature: 73 °F (23 °C, 296 K), medium temperature: 73 °F (23 °C, 296 K) medium pressure p : 0 bar, medium: dielectric constant = 2.6, conductivity: < 1 µS sensitivity setting: C
Vibration resistance a(RMS) = 50 m/s , ASD = 1.25 (m/s ) /Hz, f = 5 to 2000 Hz, t = 3 x 2 h
Dimensions max. ∅94 mm (3.7 inch), length 140 mm (5.5 inch) + L L = 500 ... 6000 mm (19.7 ... 236 inch)
Process connection thread R1-1/2 acc. to EN 10226, BSPT thread NPT1-1/2 to ANSI B 1.20.1
Hysteresis vertical 5 mm (0.2 inch)
Measuring method A metal plate at the end of the probe, within the insulation, and the surroundings (e. g. the silo walls) combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the LCL switches.
EU-type examination certificate see instruction manuals (SI)
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Switch-on delay correct switching after max. 2 s
Directive 2014/30/EU EN 61326-1:2006 , EN 61326-2-3:2006
Shock resistance device with F34 housing: 7 J
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009
Equipment architecture The measuring system consists of: - the device - a supply point - the connected control systems, switching units, signalling systems (e. g. lamps, horns, PCS, PLC, etc.)
Optional accessories LCL-Z10 cover with sight glass for F14 housing LCL-Z14 rope shortening set
Directive 2014/35/EU EN 61010-1:2010
Current consumption electrical connection E5: max. 30 mA, reverse-polarity-proof electrical connection WA: max. 130 mA
Surge protection overvoltage category III
Installation position vertically down
Mounting location The capacitive limit switch can be installed in silos made of different materials (e. g. metal, plastic, concrete).
Measured variable limit level (limit value)
Climate class EN 60068, part 2-38 (test Z/AD)
Influence of medium temperature depending on the filling material
Switching time approx. 0.8 s when covering and uncovering the sensor
State of aggregation solids
Solid contents ≤ ∅ 30 mm
Supplementary documentation technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI)
Process temperature -40 ... 80 °C (-40 ... 176 °F)
Long-term drift vertical 6 mm (0.24 inch)
Signal on alarm connection E5: < 100 µA connection WA: relay de-energized
Medium pressure limits -1 ... 6 bar
Bulk density ≤ 200 g/l

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено