  • LED status indicator of bus communication and read/write heads
  • Max. 2 read/write heads can be connected
  • Alternatively 1 read/write head and 1 trigger sensor can be connected
Параметр Значение
Общие характеристики
Артикул 44460
MTTF 170 a
Mission Time (T 10 a
Diagnostic Coverage (DC) 0 %
Ripple ≤ 10 % at 30 V DC
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Degree of protection IP67
Connection Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M8 connector CC-Link: M12 connector, A-coded
Housing powder coated aluminum
Mass approx. 300 g
Power consumption 3.5 W Without read/write heads
Interface type Diagnostic Interface
Transfer rate 38.4 kBit/s
Protocol ASCII
Installation screw fixing
Shock and impact resistance Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Directive 2014/30/EU EN 61000-6-2:2005, EN 61000-6-4:2007
Physical RS 232
Galvanic isolation basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 V
Rotary switch Address setting 01 ... 64 (decimal) Station no.: 0 ... 6 (x10) Station no.: 0 ... 9 (x1) Baud rate setting: 0 ... 4 Extended cyclic setting: 0, 1, 2, 4, 8
Climatic conditions air humidity max. 96 % Salt spray resistant to EN 60068-2-52
Current consumption ≤ 4 A incl. read/write heads
Rated operating voltage 20 ... 30 V DC , PELV
UL File Number E87056
LED PWR/ERR green: power on red: Hardware fault
Number of read/write heads max. 2 alternatively 1 read/write head and 1 trigger sensor
LEDs 1, 2 Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed
LEDs CH1, CH2 green: read head detected red: Configuration error
LED L RUN green: on, data communication active
LED L ERR red: on, invalid rotary switch setting or data transfer failure red: flashing, rotary switch setting changed since last switched on