Параметр | Значение |
Общие характеристики | |
Артикул | 6844 |
Operating voltage | 10 ... 30 V DC , ripple 10 % |
No-load supply current | ≤ 50 mA |
Repeat accuracy | ≤ 0.1 % of full-scale value |
Switching frequency | ≤ 2.5 Hz |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | 0 ... 70 °C (32 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP65 |
Housing | Stainless steel 1.4305 / AISI 303 O-ring for cover seal: Viton |
Mass | 140 g |
Interface type | RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit |
Voltage drop | ≤ 2.5 V |
Temperature influence | ≤ 2 % from full-scale value (with temperature compensation) ≤ 0.2 %/K (without temperature compensation) |
Output type | 2 switch outputs PNP, NO/NC, programmable |
CSA approval | cCSAus Listed, General Purpose |
Connection type | Connector plug M12 x 1 , 5-pin |
Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 |
LED green | solid: Power-on flashing: Standby mode or program function object detected |
Adjustment range | 120 ... 1000 mm |
Sensing range | 80 ... 1000 mm |
Dead band | 0 ... 80 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 175 kHz |
Response delay | 65 ms minimum 195 ms factory setting |
LED red | solid: temperature/program plug not connected flashing: fault or program function object not detected |
Transducer | PTFE (diaphragm surface) |
Rated operating current | 200 mA , short-circuit/overload protected |
Range hysteresis | 1 % of the adjusted operating range (default settings), programmable |
Output 1 | Switching point: 120 mm output function: Switch point operation mode output behavior: NO contact |
Output 2 | Switching point: 1000 mm output function: Switch point operation mode output behavior: NO contact |
Synchronization | bi-directional 0 level -U ...+1 V 1 level: +4 V...+U input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
Common mode operation | max. 30 Hz |
Multiplex operation | ≤ 30 Hz / n , n = number of sensors , n ≤ 5 |
LED yellow 1 | solid: switching state switch output 1 flashing: program function |
LED yellow 2 | solid: switching state switch output 2 flashing: program function |
Temperature/TEACH-IN connector | Temperature compensation , Switch points programming , output function setting |