| Параметр | Значение |
| Общие характеристики | |
| Артикул | 86304 |
| Light type | Integrated LED lightning (red/blue) |
| Ambient light limit | 30000 Lux |
| MTTF | 104.74 a |
| Mission Time (T | 20 a |
| Operating voltage | 20 ... 30 V DC , PELV |
| No-load supply current | max. 300 mA |
| CE conformity | CE |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Degree of protection | IP67 |
| Housing | PC/ABS |
| Mass | approx. 200 g |
| Power consumption | 6 W |
| Type | CMOS , Global shutter |
| Relative humidity | 90 % , noncondensing |
| Altitude | max. 2000 m above MSL |
| Interface type | 100 BASE-TX |
| Housing width | 70 mm |
| Housing depth | 50 mm |
| Transfer rate | 100 MBit/s |
| Housing height | 70 mm |
| Protocol | PROFINET IO Real-Time (RT) Conformance class B |
| Vibration resistance | EN 60068-2-6:2008 |
| Connection type | 8-pin, M12x1 connector, standard 4-pin, M12x1 socket, D-coded (LAN) 4-pin, M12x1 socket, D-coded (LAN) |
| Emitted interference | EN 61000-6-4:2007+A1:2011 |
| Noise immunity | EN 61000-6-7:2015 |
| LED indication | 7 LEDs (communication, status messages) |
| Shock resistance | EN 60068-2-27:2009 |
| Operating temperature | 0 ... 45 °C (32 ... 113 °F) , -20 ... 45 °C (-4 ... 113 °F) (noncondensing; prevent icing on the lens!) |
| Safety Integrity Level (SIL) | SIL 3 |
| Fieldbus standard | PROFIsafe in accordance with IEC 61784-3-3; profile 2.4 |
| Category | Cat. 4 |
| Performance level (PL) | PL e |
| Functional safety | EN ISO 13849-1:2015 ; EN 61508:2010 part 1-7 ; EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
| TÜV approval | TÜV Rheinland 01/205/5669.00/18 |
| PFH | 1.09 E-8 typ. |
| Read distance | 100 mm |
| Depth of focus | ± 30 mm |
| Measuring range | max. 100000 m |
| Passage speed | ≤ 8 m/s |
| Clock pulse frequency | 600 MHz |
| Speed of computation | 4800 MIPS |
| Field of view | typ. 120 mm x 80 mm |
| Safety-related X | See the original instructions |
| Reaction time | 165 ms |
| Photobiological safety | risk group 2 according IEC 62471 |
| Non safety-related X | ± 0.2 mm |