Параметр | Значение |
Общие характеристики | |
Артикул | 31117 |
MTTF | 210 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 18 ... 30 V DC |
No-load supply current | ≤ 40 mA |
Repeat accuracy | ± 0.2 mm |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Degree of protection | IP65 |
Housing | PA 6 / AL |
Housing length L | 400 mm |
Measurement range | 0 ... 360 mm |
Note | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 6 mm. |
Resolution | 360 µm |
Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
Linearity error | ± 0.4 mm |
Output type | 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V |
Load resistor | current output: ≤ 400 Ω voltage output: ≥ 1000 Ω |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | voltage output: pulsing |
Connection type | 4-pin, M12 x 1 connector |
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 |
Switching element function | analog, current or voltage output |
Object distance | max. 6 mm |
Operating voltage indicator | LED green |
Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |