Параметр | Значение |
Общие характеристики | |
Артикул | 91587 |
MTTF | 365 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized) |
No-load supply current | ≤ 40 mA |
Repeat accuracy | ± 0.1 mm |
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure |
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
Degree of protection | IP67 / IP69K |
Housing | PBT, stainless steel 1.4571 , brass, nickel-plated |
Mass | 56 g |
Interface type | IO-Link (via C/Q = Pin 4) |
IO-Link Revision | 1.1 |
Min. cycle time | 2.3 ms |
Process data witdh | Process data input: 16 Bit Process data output: none |
SIO mode support | yes |
Device ID | 0x200203 (2097667) |
Voltage drop | ≤ 3 V |
Measurement range | 0 ... 40 mm |
Resolution | 50 µm |
Device profile | Smart Sensor |
Transfer rate | COM 2 (38.4 kBaud) |
Compatible master port type | A |
Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
Operating current | ≤ 100 mA / output |
Output type | 1 current output: 4 ... 20 mA or 1 voltage output: 0 ... 10 V , programmable |
Load resistor | current output: ≤ 400 Ω voltage output: ≥ 1000 Ω |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | voltage output: current limit |
Connection type | 5-pin, M12 x 1 connector |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 EN 60947-5-7:2003 EN61131-9:2013 IEC 60947-5-7:2003 IEC 61131-9:2013 |
Switching element function | Analog current or voltage output, programmable 2 switch outputs, programmable |
Object distance | 0.5 ... 3 mm , recommended: 1.5 mm |
Linearity range | 1 ... 39 mm |
Operating voltage indicator | LED green |
Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
Switching window | ± 1 mm |
Switching hysteresis | 0.2 mm |
LED S1 | switching state Switching output 1 |
LED S2 | switching state Switching output 2 |
LED S3 | Damping element in the configured analog measuring range |
LED STATUS | Status display LED, green/red (Power on, communication/error, missing damping element) |
Value range | 0000h ... 3200h |