Safety light grid with integrated control unit SLC-4

Safety light grid with integrated control unit SLC-4
Safety light grid with integrated control unit SLC-4

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 3770
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Sensing range up to 20 m
  • 2, 3, and 4-beam design
  • Beam distance 300, 400 and 500 mm
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Start/Restart disable
  • Degree of protection IP67
  • 7-segment diagnostic display
  • Pre-fault indication
  • Safety outputs OSSD in potential-separated semiconductor design or with monitored, compelled connection NC-contacts
Параметр Значение
Общие характеристики
Артикул 3770
Light source IRED
Light type modulated infrared light
Tests IEC/EN 61496
Target size 50 mm
Mission Time (T 20 a
Function indicator in receiver: LED red: OSSD off LED green: OSSD on LED yellow: Protected area free, system start-ready
Control elements switch for start/restart disable, transmission coding
Operating voltage 24 V DC (-30 %/+25 %)
No-load supply current Emitter: 100 mA , receiver 150 mA
Signal output 1 PNP each, max. 100 mA for start readiness and OSSD status
Switching voltage Operating voltage -2 V
Switching current max. 0.5 A
Response time 10 ms
Product standard EN 61496-1 ; IEC 61496-2
CE conformity CE
UL approval cULus Listed
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient temperature 0 ... 55 °C (32 ... 131 °F)
Storage temperature -25 ... 70 °C (-13 ... 158 °F)
Degree of protection IP67
Connection M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm
Housing extruded aluminum profile, RAL 1021 (yellow) coated
Optical face Plastic pane
Mass Per 3450 g
Type 4
Relative humidity max. 95 %, not condensing
Effective detection range 0.2 ... 20 m
Beam spacing 300 mm
Number of beams 4
Operating mode can be selected with or without start/restart disable
Angle of divergence < 5 °
Operation indicator 7-segment display in emitter
Test input Reset-input for system test
Function input Start release
Protection class III
LED risk group labelling exempt group
Emitter SLC-4-T
Receiver SLC-4-R
Safety Integrity Level (SIL) SIL 3
Category Cat. 4
Diagnostics indicator 7-segment display in receiver
Performance level (PL) PL e
Functional safety ISO 13849-1
TÜV approval TÜV
PFH 7.27 E-9
Activation current approx. 10 mA
Pre-fault indicator LED orange
Safety output 2 separated fail safe semiconductor outputs
Safety type according to IEC/EN 61496 4
Activation time 0.03 ... 1 s
Connection options Further electrical connection options on request: Connector M12, 8-pin Connector DIN 43 651 Hirschmann, 6-pin+PE Connector M26x11 Hirschmann, 11-pin+PE