Параметр | Значение |
Общие характеристики | |
Артикул | 97414 |
Light source | laser diode |
Light type | red laser + Integrated LED lightning red 650 nm |
MTTF | 20 a |
Mission Time (T | 10 a |
Diagnostic Coverage (DC) | 0 % |
Function indicator | Trigger: LED yellow ; object detected : LED red / green |
Control elements | 2 push-buttons |
Operating voltage | 24 V ± 20 % , PELV |
No-load supply current | max. 250 mA |
Switching type | PNP |
Switching voltage | 24 V |
Switching current | 150 mA each output |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Storage temperature | -20 ... 70 °C (-4 ... 158 °F) |
Degree of protection | IP67 |
Connection | 8-pin, M12 x 1 connector ( supply + RS485 + Inputs/Outputs ) ; can be rotated 90° ; Grounding : Grounding clip for PCV system |
Housing | PC/ABS |
Optical face | Plastic pane |
Mass | approx. 125 g |
Power consumption | max. 6 W , Outputs without load |
Operation indicator | LED green |
Interface type | RS 485 interface |
Switching threshold | low: < 2.5 V, high: > 8 V |
Measurement range | X = 60 ... 300 mm ; Z = 100 ... 700 mm |
Note | - Read the operating instructions before attempting commissioning - Installation, connection and adjustments should only be undertaken by specialist personnel - Not a safety component in accordance with the EU Machinery Directive |
Laser class | IEC 60825-1:2007 |
Wave length | Measurement laser: 660 nm |
Pulse length | Measurement laser: 0.5 ms |
Resolution | X > 0.44 mm ; Z > 0.4 mm at min. read distance |
Transfer rate | 38400 ... 230400 Bit/s |
Protocol | binary code |
Approvals | CE |
Maximum optical power output | Measurement laser: 15 mW |
Shock and impact resistance | EN 60068-2-27:2009 |
Scan rate | 15 s |
Tightening torque, fastening screws | max. 2 Nm |
Emitted interference | EN 61000-6-4:2007/A1:2011 |
Noise immunity | EN 61000-6-2:2005 |
Operating temperature | -20 ... 45 °C (-4 ... 113 °F) , (noncondensing; prevent icing on the lens!) |
Physical | Switchable terminal resistor |
Input voltage | 24 V |
Number/Type | 2 digital outputs |
Diagnostics indicator | LED yellow / red |
Laser monitoring | The safety system switches off the laser when the laser current is too high |