Параметр | Значение |
Общие характеристики | |
Артикул | 92210 |
MTTF | 362 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 10 ... 30 V DC |
No-load supply current | ≤ 15 mA |
Switching frequency | 0 ... 2000 Hz (switch point mode) 0 ... 125 Hz (window mode, switch point mode with stability alarm) |
UL approval | cULus Listed, General Purpose Class 2 power source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP67 |
Mass | 25 g |
Status indicator | Multihole-LED, yellow |
Time delay before availability | max. 150 ms |
Interface type | IO-Link ( via C/Q = pin 4 ) |
IO-Link Revision | 1.1 |
Min. cycle time | 2.3 ms |
Process data witdh | Process data input (control system side): 2 Bit Process data output (control system side): none |
SIO mode support | yes |
Device ID | 0x201111 (2101521) |
Voltage drop | ≤ 0.5 V |
Protection class | II |
Transfer rate | COM 2 (38.4 kBaud) |
Compatible master port type | A |
Operating current | 0 ... 200 mA |
Output type | 3-wire |
Switching function | Normally open/closed (NO/NC) programmable |
Rated operating distance | 4 mm (factory setting) |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 ... 3.24 mm |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Connection type | Connector plug M12 x 1 , 4-pin |
Housing material | Brass, PTFE coated |
Sensing face | PPS |
Hysteresis | typ. 3 % |
Off-state current | 0 ... 0.5 mA typ. 60 µA at 25 °C |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Rated impulse withstand voltage | 800 V |
Rated insulation voltage | 60 V |
Scope of delivery | 2 self locking nuts in scope of delivery |
Default setting | operating mode = switch point mode with stability alarm switching function = Normally open (NO) switching distance = 4 mm |
Reduction factor r | 1 |
Near operating distance | 3 mm (can be activated by software) |
Constant magnetic field | 200 mT |
Alternating magnetic field | 200 mT |