Параметр | Значение |
Общие характеристики | |
Артикул | 60042 |
MTTF | 10660 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Switching frequency | 0 ... 200 Hz |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
Degree of protection | IP68 |
Note | only for non-ferrous metal |
Bending radius | > 10 x cable diameter |
Output type | 2-wire |
Type of protection | intrinsic safety |
Cable diameter | 6.8 mm ± 0.2 mm |
Switching function | Normally open (NO) |
Rated operating distance | 3 mm |
Installation | flush in mild steel |
Assured operating distance | 0 ... 2.4 mm |
Connection type | cable silicone , 5 m |
Housing material | Crastin (PBT), black |
Sensing face | Crastin (PBT), black |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 |
Core cross-section | 0.75 mm |
EAC conformity | TR CU 012/2011 |
CE marking | [*PD-Z02586A*] |
Safety Integrity Level (SIL) | SIL 3 |
Control drawing | 116-0454 |
IECEx certificate | IECEx PTB 11.0092X |
IECEx marking | Ex ia I Mb |
Nominal voltage | 8.2 V |
ATEX marking | II 3D Ex tc IIIC T80°C Dc |
Appropriate type | NJ 3-18GK-S1N... |
Effective internal capacitance | max. 70 nF A cable length of 10 m is considered. |
Effective internal inductance | max. 200 µH A cable length of 10 m is considered. |
Use in the hazardous area | see instruction manuals |
Actual operating distance | 2.7 ... 3.3 mm typ. |
Measuring plate not detected | ≤ 1 mA |
Measuring plate detected | ≥ 3 mA |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at U = 16 V , I = 25 mA , P = 34 mW : 100 °C (212 °F) at U = 16 V , I = 25 mA , P = 64 mW : 100 °C (212 °F) at U = 16 V , I = 52 mA , P = 169 mW : 80 °C (176 °F) at U = 16 V , I = 76 mA , P = 242 mW : 61 °C (141.8 °F) |
Equipment protection level | Ga , Gb , Gc (ic) , Gc (nA) , Da , Dc , Mb |
ATEX certificate | PF 15 CERT 3774 X |
Possible characteristics | maximum operating voltage U , maximum load current I , minimum series resistance R , maximum analog output voltage U , maximum analog output current I |
Reduction factor r | 0 |
Ordinary Location | E87056 |
Hazardous Location | E501628 |
for ATEX | at U = 16 V , I = 25 mA , P = 34 mW , T6 : 57 °C (134.6 °F) T5 : 69 °C (156.2 °F) T4 : 97 °C (206.6 °F) T3 : 97 °C (206.6 °F) T2 : 97 °C (206.6 °F) T1 : 97 °C (206.6 °F) at U = 16 V , I = 25 mA , P = 64 mW , T6 : 52 °C (125.6 °F) T5 : 64 °C (147.2 °F) T4 : 92 °C (197.6 °F) T3 : 92 °C (197.6 °F) T2 : 92 °C (197.6 °F) T1 : 92 °C (197.6 °F) at U = 16 V , I = 52 mA , P = 169 mW , T6 : 34 °C (93.2 °F) T5 : 46 °C (114.8 °F) T4 : 74 °C (165.2 °F) T3 : 74 °C (165.2 °F) T2 : 74 °C (165.2 °F) T1 : 74 °C (165.2 °F) at U = 16 V , I = 76 mA , P = 242 mW , T6 : 22 °C (71.6 °F) T5 : 34 °C (93.2 °F) T4 : 61 °C (141.8 °F) T3 : 61 °C (141.8 °F) T2 : 61 °C (141.8 °F) T1 : 61 °C (141.8 °F) |
for IECEx | at U = 16 V , I = 25 mA , P = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U = 16 V , I = 25 mA , P = 64 mW , T6 : 69 °C (156.2 °F) T5 : 84 °C (183.2 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U = 16 V , I = 52 mA , P = 169 mW , T6 : 51 °C (123.8 °F) T5 : 66 °C (150.8 °F) T4 : 80 °C (176 °F) T3 : 80 °C (176 °F) T2 : 80 °C (176 °F) T1 : 80 °C (176 °F) at U = 16 V , I = 76 mA , P = 242 mW , T6 : 39 °C (102.2 °F) T5 : 54 °C (129.2 °F) T4 : 61 °C (141.8 °F) T3 : 61 °C (141.8 °F) T2 : 61 °C (141.8 °F) T1 : 61 °C (141.8 °F) |