Пт-Пн: 9:00 - 18:00

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Цены носят информационный характер и не являются публичной офертой. Точную цену и срок поставки подтвердит менеджер при оформлении заявки
Доставка в любой регион России транспортной
компанией на Ваш выбор
| Параметр | Значение |
| Общие характеристики | |
| Артикул | 469 |
| MTTF | 6150 a |
| Mission Time (T | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Operating voltage | 5 ... 25 V |
| Switching frequency | 0 ... 2000 Hz |
| UL approval | cULus Listed, General Purpose |
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Degree of protection | IP67 |
| Mass | 36 g |
| Electromagnetic compatibility | NE 21:2007 |
| Bending radius | > 10 x cable diameter |
| Length | 4 mm |
| Output type | 2-wire |
| Cable diameter | 2.6 mm ± 0.2 mm |
| Switching function | Normally closed (NC) |
| CSA approval | cCSAus Listed, General Purpose |
| Connection type | cable PVC , 2 m |
| Housing material | PBT |
| Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions |
| Core cross-section | 0.14 mm |
| CE marking | [*PD-Z02585A*] |
| Inside diameter | 10 mm |
| Control drawing | 116-0165 |
| Nominal voltage | 8.2 V (R approx. 1 kΩ) |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| ATEX marking | II 2G Ex ia IIC T6…T1 Gb The Ex-related marking can also be printed on the enclosed label. |
| Appropriate type | RC10-...-N0... |
| Effective internal capacitance | max. 150 nF ; a cable length of 10 m is considered. |
| Effective internal inductance | max. 100 µH ; a cable length of 10 m is considered. |
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
| Measuring plate not detected | min. 3 mA at maximum permissible ambient temperature, the current consumption can drop to 1.6 mA |
| Measuring plate detected | ≤ 1 mA |
| Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
| Diameter | 2.5 mm |
| Suitable for 21 technology | yes , Reverse polarity protection diode not required |
| Measuring cylinder | 9S20K |