| Параметр | Значение |
| Общие характеристики | |
| Артикул | 44247 |
| Switching frequency | 0 ... 1000 Hz |
| Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
| Degree of protection | IP67 |
| Bending radius | > 10 x cable diameter |
| Output type | 2-wire |
| Switching function | Normally closed (NC) |
| Rated operating distance | 2 mm |
| Installation | flush |
| Assured operating distance | 0 ... 1.62 mm |
| CSA approval | cCSAus Listed, General Purpose |
| Connection type | cable PVC , 170 mm |
| Housing material | PBT |
| Sensing face | PBT |
| Hysteresis | 0.01 ... 0.1 mm |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions |
| Core cross-section | 0.14 mm |
| CE marking | [*PD-Z02585A*] |
| Control drawing | 116-0451 |
| Nominal voltage | 8 V |
| NAMUR | EN 60947-5-6:2000 |
| ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. |
| Appropriate type | NJ 2-V3-N ... |
| Effective internal capacitance | max. 40 nF ; a cable length of 10 m is considered. |
| Effective internal inductance | max. 50 µH ; a cable length of 10 m is considered. |
| Use in the hazardous area | see instruction manuals |
| Category | 1G; 2G; 1D |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. |
| Reduction factor r | 0.7 |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |