| Параметр | Значение |
| Общие характеристики | |
| Артикул | 31875 |
| MTTF | 2040 a |
| Mission Time (T | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Switching frequency | 0 ... 300 Hz |
| UL approval | cULus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Degree of protection | IP67 |
| Electromagnetic compatibility | NE 21:2007 |
| Bending radius | > 10 x cable diameter |
| Output type | 2-wire |
| Cable diameter | 6 mm ± 0.2 mm |
| Switching function | Normally closed (NC) |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 6.48 mm |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Switching state indicator | all direction LED, yellow |
| CSA approval | cCSAus Listed, General Purpose |
| Connection type | cable PVC , 2 m |
| Housing material | PBT |
| Sensing face | PBT |
| Hysteresis | 1 ... 10 typ. 5 % |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions |
| Core cross-section | 0.75 mm |
| CE marking | [*PD-Z02585A*] |
| Control drawing | 116-0165 |
| Nominal voltage | 8.2 V (R approx. 1 kΩ) |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. |
| Appropriate type | NCN8-18GK...-N0... |
| Effective internal capacitance | max. 95 nF ; a cable length of 10 m is considered. |
| Effective internal inductance | max. 100 µH ; a cable length of 10 m is considered. |
| Use in the hazardous area | see instruction manuals |
| Category | 2G; 1D |
| Actual operating distance | 7.2 ... 8.8 mm typ. 8 mm |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. |
| Reduction factor r | 0.7 |