Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Inductive sensor NCB2-12GM35-N0-V1 31777

Inductive sensor NCB2-12GM35-N0-V1

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 31777
Под заказ
Запрос цены

Цены носят информационный характер и не являются публичной офертой. Точную цену и срок поставки подтвердит менеджер при оформлении заявки

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 2 mm flush
  • Usable up to SIL 2 acc. to IEC 61508
Параметр Значение
Общие характеристики
Артикул 31777
MTTF 2099 a
Mission Time (T 20 a
Diagnostic Coverage (DC) 0 %
Operating voltage 5 ... 25 V
Switching frequency 0 ... 1000 Hz
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Degree of protection IP66 / IP67
Electromagnetic compatibility NE 21:2007
Output type 2-wire
Switching function Normally closed (NC)
Rated operating distance 2 mm
Installation flush
Assured operating distance 0 ... 1.62 mm
Reverse polarity protection reverse polarity protected
Short-circuit protection yes
Switching state indicator Multihole-LED, yellow
CSA approval cCSAus Listed, General Purpose
Connection type Connector plug M12 x 1 , 4-pin
Housing material Stainless steel 1.4305 / AISI 303
Sensing face PBT
Hysteresis 1 ... 10 typ. 5 %
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
EAC conformity TR CU 012/2011
CE marking [*PD-Z02585A*]
Scope of delivery 2 self locking nuts in scope of delivery
Certificate PF 13 CERT 2895 X
Control drawing 116-0452
Nominal voltage 8.2 V (R approx. 1 kΩ)
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
Appropriate type NCB2-12GM...-N0...
Effective internal capacitance max. 90 nF ; a cable length of 10 m is considered.
Effective internal inductance max. 100 µH ; a cable length of 10 m is considered.
Use in the hazardous area see instruction manuals
Category 1G; 2G; 1D
Actual operating distance 1.8 ... 2.2 mm typ.
Measuring plate not detected ≥ 2.2 mA at nominal voltage
Measuring plate detected ≤ 1 mA at nominal voltage
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate.
Reduction factor r 0.7
Ordinary Location E87056
Hazardous Location E501628
for Pi=34 mW, Ii=25 mA, T6 55 °C (131 °F)
for Pi=34 mW, Ii=25 mA, T5 55 °C (131 °F)
for Pi=34 mW, Ii=25 mA, T4-T1 55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T6 55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T5 55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T4-T1 55 °C (131 °F)
for Pi=169 mW, Ii=52 mA, T6 52 °C (125.6 °F)
for Pi=169 mW, Ii=52 mA, T5 52 °C (125.6 °F)
for Pi=169 mW, Ii=52 mA, T4-T1 52 °C (125.6 °F)
for Pi=242 mW, Ii=76 mA, T6 44 °C (111.2 °F)
for Pi=242 mW, Ii=76 mA, T5 44 °C (111.2 °F)
for Pi=242 mW, Ii=76 mA, T4-T1 44 °C (111.2 °F)
Suitable for 21 technology yes , Reverse polarity protection diode not required

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Пользовательского соглашения.

Спасибо!