| Параметр | Значение |
| Общие характеристики | |
| Артикул | 31756 |
| MTTF | 1914 a |
| Mission Time (T | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Switching frequency | 0 ... 300 Hz |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Degree of protection | IP67 |
| Electromagnetic compatibility | NE 21:2007 |
| Output type | 2-wire |
| Switching function | Normally closed (NC) |
| Rated operating distance | 8 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 6.48 mm |
| Reverse polarity protection | reverse polarity protected |
| Short-circuit protection | yes |
| Switching state indicator | Multihole-LED, yellow |
| CSA approval | cCSAus Listed, General Purpose |
| Connection type | Connector plug M12 x 1 , 4-pin |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Hysteresis | 1 ... 15 typ. 5 % |
| Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions |
| Core cross-section | - |
| EAC conformity | TR CU 012/2011 |
| CE marking | [*PD-Z02585A*] |
| Certificate | PF 13 CERT 2895 X |
| Control drawing | 116-0452 |
| Nominal voltage | 8.2 V (R approx. 1 kΩ) |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. |
| Appropriate type | NCN8-18GM...-N0... |
| Effective internal capacitance | max. 95 nF ; a cable length of 10 m is considered. |
| Effective internal inductance | max. 100 µH ; a cable length of 10 m is considered. |
| Use in the hazardous area | see instruction manuals |
| Category | 1G; 2G; 1D |
| Actual operating distance | 7.2 ... 8.8 mm typ. 8 mm |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. |
| Reduction factor r | 0.72 |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| for Pi=34 mW, Ii=25 mA, T6 | 55 °C (131 °F) |
| for Pi=34 mW, Ii=25 mA, T5 | 55 °C (131 °F) |
| for Pi=34 mW, Ii=25 mA, T4-T1 | 55 °C (131 °F) |
| for Pi=64 mW, Ii=25 mA, T6 | 55 °C (131 °F) |
| for Pi=64 mW, Ii=25 mA, T5 | 55 °C (131 °F) |
| for Pi=64 mW, Ii=25 mA, T4-T1 | 55 °C (131 °F) |
| for Pi=169 mW, Ii=52 mA, T6 | 52 °C (125.6 °F) |
| for Pi=169 mW, Ii=52 mA, T5 | 52 °C (125.6 °F) |
| for Pi=169 mW, Ii=52 mA, T4-T1 | 52 °C (125.6 °F) |
| for Pi=242 mW, Ii=76 mA, T6 | 44 °C (111.2 °F) |
| for Pi=242 mW, Ii=76 mA, T5 | 44 °C (111.2 °F) |
| for Pi=242 mW, Ii=76 mA, T4-T1 | 44 °C (111.2 °F) |