Параметр | Значение |
Общие характеристики | |
Артикул | 14602 |
MTTF | 1510 a |
Mission Time (T | 20 a |
Diagnostic Coverage (DC) | 0 % |
Operating voltage | 10 ... 30 V DC |
No-load supply current | ≤ 20 mA |
Switching frequency | 0 ... 180 Hz |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Degree of protection | IP69K |
Time delay before availability | 80 ms |
Voltage drop | ≤ 2 V |
Protection class | II |
Operating current | 0 ... 200 mA |
Output type | 3-wire |
Switching function | Normally open (NO) |
Rated operating distance | 40 mm |
Installation | non-flush |
Output polarity | DC |
Assured operating distance | 0 ... 32.4 mm |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Switching state indicator | LED, yellow |
Connection type | Connector plug M12 x 1 , 4-pin |
Housing material | PA-GF35 metal base Xylan coated metal mounting flange Xylan coated. |
Sensing face | PA-GF35 |
Hysteresis | typ. 5 % |
Off-state current | 0 ... 0.5 mA |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
Rated impulse withstand voltage | 4000 V |
Rated insulation voltage | 253 V |
Operating voltage indicator | LED, green |
Actual operating distance | 36 ... 44 mm |
Reduction factor r | 0.38 |