| Параметр | Значение |
| Общие характеристики | |
| Артикул | 12148 |
| MTTF | 2424 a |
| Mission Time (T | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Switching frequency | 0 ... 100 Hz |
| UL approval | cULus Listed, General Purpose |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Degree of protection | IP67 |
| Output type | 2-wire |
| Switching function | Normally closed (NC) |
| Rated operating distance | 15 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 12.15 mm |
| Switching state indicator | LED, yellow |
| CSA approval | cCSAus Listed, General Purpose |
| Connection type | screw terminals |
| Housing material | PBT |
| Sensing face | PBT |
| Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions |
| Core cross-section | up to 2.5 mm |
| CE marking | [*PD-Z02585A*] |
| Nominal voltage | 8.2 V (R approx. 1 kΩ) |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. |
| Appropriate type | NJ15-M1K-N... |
| Effective internal capacitance | max. 130 µF A cable length of 10 m is considered. |
| Effective internal inductance | max. 80 µH A cable length of 10 m is considered. |
| Use in the hazardous area | see instruction manuals |
| Category | 2G |
| Actual operating distance | 13.5 ... 16.5 mm typ. |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
| Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
| Minimum core cross-section | without wire end ferrule 0.5 mm , with connector sleeves 0.34 mm |
| Maximum core cross-section | without wire end ferrule 2.5 mm , with connector sleeves 1.5 mm |
| Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
| Reduction factor r | 0.8 |