Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Capacitive sensor CJ1-12GK-N 9892

Capacitive sensor CJ1-12GK-N

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 9892
Под заказ
Запрос цены

Цены носят информационный характер и не являются публичной офертой. Точную цену и срок поставки подтвердит менеджер при оформлении заявки

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 1 mm non-flush
Параметр Значение
Общие характеристики
Артикул 9892
MTTF 5670 a
Mission Time (T 20 a
Diagnostic Coverage (DC) 0 %
Operating voltage 7 ... 12 V
Switching frequency 0 ... 1 Hz
UL approval cULus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Degree of protection IP68
Bending radius > 10 x cable diameter
Output type 2-wire
Switching function Normally open (NO)
Rated operating distance 1 mm
Installation non-flush
Assured operating distance 0 ... 0.72 mm
A 5 mm
B 15 mm
C 12 mm
F 70 mm
CSA approval cCSAus Listed, General Purpose
Connection type cable PVC , 2 m
Housing material PBT
Sensing face PBT
Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions
Core cross-section 0.34 mm
CE marking [*PD-Z02585A*]
Control drawing 116-0165
Nominal voltage 8.2 V (R approx. 1 kΩ)
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
Appropriate type CJ1-12GK-N...
Effective internal capacitance max. 60 nF ; a cable length of 10 m is considered.
Effective internal inductance negligibly small A cable length of 10 m is considered.
Use in the hazardous area see instruction manuals
Category 1G; 2G; 1D
Measuring plate not detected ≤ 1 mA
Measuring plate detected ≥ 2.4 mA
Highest permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Пользовательского соглашения.

Спасибо!

Ваше сообщение успешно отправлено