Корзина 0 0
Электротехническое оборудование

Пт-Пн: 9:00 - 18:00

Fieldbus Surge Protector for Cabinet Installation, Ex ia DP-LBF-I1.36.*

Fieldbus Surge Protector for Cabinet Installation, Ex ia DP-LBF-I1.36.*
Fieldbus Surge Protector for Cabinet Installation, Ex ia DP-LBF-I1.36.*

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 44673
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Modular: protection module easy to replace
  • Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose
  • Protection module replaceable, interrupting or non-interrupting
  • Grounding of shield direct or via gas-discharge tube
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Compact and space-saving design
  • Installation on DIN rail in cabinet or field junction box
Параметр Значение
Общие характеристики
Артикул 44673
Ambient temperature -50 ... 80 °C (-58 ... 176 °F)
Storage temperature -50 ... 85 °C (-58 ... 185 °F)
Degree of protection IP20
Mass Protection Module 20 g , base module 40 g
Rated voltage 33 V
Relative humidity ≤ 95 % non-condensing
Mounting 35 mm DIN mounting rail
Current 500 mA
Marking II 3G Ex ic IIC T4/T5/T6 Gc , II 3G Ex nA IIC T4/T5/T6 Gc
Vibration resistance 1 g , 10 ... 150 Hz
CSA approval CSA 2437472
Connection type screw terminals
Housing material Polyamide PA 6.6
Core cross-section flexible wire 2.5 mm solid wire max. 4 mm
EU-type examination certificate KEMA 09 ATEX 0191 X
IECEx approval IECEx KEM 09.0088X
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Approved for Ex ia [ia Ga] IIC T4/T5/T6 Gb , Ex ic IIC T4/T5/T6 Gc , Ex nA IIC T4/T5/T6 Gc
Rated current 500 mA
Directive 2014/30/EU EN 61326-1:2013
Shock resistance 15 g 11 ms
Certificate KEMA 09 ATEX 0190 X
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007
Control drawing 116-0361
Design / Mounting Cabinet installation
Marine approval pending
Fieldbus standard IEC 61158-2
Voltage 33 V
Climatic conditions IEC 60721
Surge protection IEC 61643-21
Internal capacitance negligible 0 nF
Internal inductance negligible 0 µH
Line/Line 800 pF
Line/Earth 16 pF
Overstressed fault mode acc. IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec)
Series resistance in line 1 Ω +/- 5 %
Per line 1 kA category D1 10/350µsec , 5 kA category C1/C2 8/20µsec
Screen/Shield indirectly grounded (via GDT) 4 kA category D1 10/350µsec , 10 kA category C1/C2 8/20µsec
Screen/Shield-Earth max. 100 ns
Screen/Shield directly grounded 5 kA category D1 10/350µsec

Техподдержка

Опишитите свой вопрос, специалист службы технической поддержки свяжется с Вами в течении нескольких часов

Отправляя заявку, вы принимаете условия Политики конфиденциальности.

Спасибо!

Ваше сообщение успешно отправлено