Thermocouple Converter LB5102A

Thermocouple Converter LB5102A
Thermocouple Converter LB5102A

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 59318
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 1-channel
  • Input Ex ia
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • Converter for thermocouples and mV-signals
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring
  • Module can be exchanged under voltage
Параметр Значение
Общие характеристики
Артикул 59318
UL approval E106378
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20 when mounted on backplane
Connection removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm ) or screw terminals (0.08 ... 1.5 mm )
Mass approx. 90 g
Rated voltage 12 V DC , only in connection with the power supplies LB9***
Power consumption 0.45 W
Electromagnetic compatibility NE 21
Relative humidity 95 % non-condensing
Current 43 mA
Measurement range -75 ... mV ... 75 mV
Linearity error 0.1 %
Marking II 3 G Ex nA IIC T4 Gc
Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Dimensions 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
EU-type examination certificate PTB 03 ATEX 2042 X
IECEx approval BVS 09.0037X
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Approved for Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC
System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Power 67 mW (trapezoid characteristic curve)
LED indication Power LED (P) green: supply Status LED (1) red: line fault
Directive 2014/30/EU EN 61326-1
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Certificate PF 08 CERT 1234 X
Directive 2014/34/EU EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 EN 61241-11:2006
Power dissipation 0.45 W
Control drawing 116-0322
Voltage 1.8 V
Line fault detection can be switched on/off for each channel via configuration tool ,
ATEX approval PTB 03 ATEX 2042 X
Open-circuit > 1 kΩ
Influence of ambient temperature max. 0,1 %/10 K
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Compensation (reference junction CJC) internal cold junction compensation or external cold junction
Interface manufacturer-specific bus to standard com unit
Coding optional mechanical coding via front socket
Occupied slots 1
Number of channels 1
Field device [2] Thermocouple
Field device [4] mV source
Conversion time internal cold junction: max. 120 ms without LFD max. 240 ms with LFD external cold junction: max. 20 ms without LFD max. 80 ms with LFD
Environmental test EN 60068-2-14
Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Lloyd Register 15/20021
Bureau Veritas Marine 22449/B0 BV
DNV GL Marine TAA0000034
Smallest span 5 mV for 0.1 % accuracy
Sensor thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources