Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 59218 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Degree of protection | IP20 when mounted on backplane |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm ) or screw terminals (0.08 ... 1.5 mm ) |
Mass | approx. 90 g |
Rated voltage | 12 V DC , only in connection with the power supplies LB9*** |
Power consumption | 0.65 W |
Electromagnetic compatibility | NE 21 |
Relative humidity | 95 % non-condensing |
Connection 2 | volt-free contact |
Marking | II 3 G Ex nA [ic] IIC T4 Gc |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
Dimensions | 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) |
Function | Counter |
IECEx approval | BVS 09.0037X |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Function 2 | frequency |
Approved for | Ex nA [ic] IIC T4 Gc |
System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. |
LED indication | Power LED (P) green: supply Status LED (1) red: line fault |
Directive 2014/30/EU | EN 61326-1 |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Certificate | PF 08 CERT 1234 X |
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 |
Power dissipation | 0.65 W |
Voltage | 8.2 V |
Line fault detection | can be switched on/off for each channel via configuration tool |
Operating frequency | 0 ... 400 Hz ; in frequency + counter mode ... 40 Hz |
Minimum pulse duration | ; in frequency + counter mode: 12.5 ms ; otherwise 20 µs |
ATEX approval | PTB 03 ATEX 2042 X |
Rated values | acc. to EN 60947-5-6 (NAMUR) |
Switching point/switching hysteresis | 1.2 ... 2.1 mA / ± 0.2 mA |
Open-circuit | < 0.35 mA |
Short-circuit | < 360 Ω |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Internal resistor | 1 kΩ |
Interface | manufacturer-specific bus to standard com unit |
Coding | optional mechanical coding via front socket |
Occupied slots | 1 |
Number of channels | 1 |
Environmental test | EN 60068-2-14 |
Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
Lloyd Register | 15/20021 |
Bureau Veritas Marine | 22449/B0 BV |
DNV GL Marine | TAA0000034 |
Function [3] | direction of rotation |