Параметр | Значение |
Общие характеристики | |
Артикул | 59307 |
UL approval | E106378 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Degree of protection | IP20 when mounted on backplane |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm ) or screw terminals (0.08 ... 1.5 mm ) |
Mass | approx. 150 g |
Rated voltage | 12 V DC , only in connection with the power supplies LB9*** |
Power consumption | 3.3 W |
Electromagnetic compatibility | NE 21:2007 |
Relative humidity | 95 % non-condensing |
Current | 87 mA |
Marking | II 3(1) G Ex nA [ia Ga] IIC T4 Gc I (M1) [Ex ia Ma] I II (1) D [Ex ia Da] IIIC |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
EU-type examination certificate | BVS 11 ATEX E 116 X |
IECEx approval | BVS 11.0068X |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Approved for | Ex nAc [ia] IIC T4 [Ex ia] IIIC [Ex ia] I |
System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. |
Power | 575 mW (linear characteristic) |
LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) |
Directive 2014/30/EU | EN 61326-1:2006 |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 EN 60079-26:2007 EN 61241-11:2006 |
Power dissipation | 2.15 W |
Voltage | 27 V |
Load | max. 750 Ω at 20 mA |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
ATEX approval | BVS 11 ATEX E 116X |
Open-circuit | deviation of preset output value > 0.5 mA |
Short-circuit | factory setting: < 50 Ω configurable between 0 ... 26 mA |
Influence of ambient temperature | 0.1 %/10 K of the signal range |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Interface | manufacturer-specific bus to standard com unit |
Coding | optional mechanical coding via front socket |
Occupied slots | 2 |
Number of channels | 4 |
Field device | Proportional Valve |
Field device [2] | I/P converters |
Field device [3] | on-site display |
HART communication | yes |
HART secondary variable | yes |
After calibration | 0.1 % of the signal range at 20 °C (68 °F) |
Refresh time | 100 ms |
Environmental test | EN 60068-2-14:2009 |
Lloyd Register | 15/20021 |
Bureau Veritas Marine | 22449/B0 BV |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |