Параметр | Значение |
Общие характеристики | |
Артикул | 59240 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Degree of protection | IP20 when mounted on backplane |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm ) or screw terminals (0.08 ... 1.5 mm ) |
Mass | approx. 150 g |
Rated voltage | 12 V DC , only in connection with the power supplies LB9*** |
Power consumption | 3.3 W |
Electromagnetic compatibility | NE 21:2007 |
Relative humidity | 95 % non-condensing |
Current | 0 ... 25 mA short-circuit protected |
Marking | II 3 G Ex nA [ic] IIC T4 Gc |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
IECEx approval | BVS 11.0068X |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Approved for | Ex nAc [ic] IIC T4 |
System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. |
LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) |
Directive 2014/30/EU | EN 61326-1:2006 |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Certificate | BVS 12 ATEX E 115 X |
Directive 2014/34/EU | EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 |
Power dissipation | 2.15 W |
Load | 750 Ω max. |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
ATEX approval | BVS 12 ATEX E 115 X |
Open-circuit | deviation of preset output value > 0.5 mA |
Short-circuit | factory setting: < 50 Ω configurable between 0 ... 26 mA |
Influence of ambient temperature | 0.1 %/10 K of the signal range |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Interface | manufacturer-specific bus to standard com unit |
Coding | optional mechanical coding via front socket |
Occupied slots | 2 |
Number of channels | 4 |
Field device | Proportional Valve |
Field device [2] | I/P converters |
Field device [3] | on-site display |
HART communication | yes |
HART secondary variable | yes |
After calibration | 0.1 % of the signal range at 20 °C (68 °F) |
Refresh time | 100 ms |
Environmental test | EN 60068-2-14:2009 |
Lloyd Register | 15/20021 |
Bureau Veritas Marine | 22449/B0 BV |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |