HART Transmitter Power Supply, Input Isolator FB3302B2

HART Transmitter Power Supply, Input Isolator FB3302B2
HART Transmitter Power Supply, Input Isolator FB3302B2

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 68677
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • 1-channel
  • Inputs with plug-in Ex e terminals
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA
  • Supply circuit 15 V (20 mA)
  • Input from active signals of 4-wire transmitters
  • HART communication via field bus or service bus
  • HART communication also for separately powered devices
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD) and Live Zero monitoring
  • Permanently self-monitoring
Параметр Значение
Общие характеристики
Артикул 68677
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Degree of protection IP20 (module) , a separate housing is required acc. to the system description
Connection Ex e spring terminal with protective cover
Mass approx. 350 g
Rated voltage 12 V DC , only in connection with the power supplies FB92**
Power consumption 1.1 W
Electromagnetic compatibility NE 21:2007
Relative humidity 95 % non-condensing
Resolution 12 Bit (0 ... 26 mA)
Connection 2 3-wire transmitter
Marking II 2 G Ex db eb IIC T4
Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Dimensions 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch)
EU-type examination certificate BVS 11 ATEX E 093 X
Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
EAC approval Russia: RU C-IT.MIII06.B.00129
INMETRO Brazil: TÜV 14.1599X
System information The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate.
LED indication Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1) red: line fault (lead breakage or short circuit) Status LED (2) yellow: Live Zero monitoring
Directive 2014/30/EU EN 61326-1:2006
Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Directive 2014/34/EU EN 60079-0:2009 EN 60079-1:2007 EN 60079-7:2007
Power dissipation 0.75 W
Connection 3 4-wire transmitter
Input resistance 15 Ω (terminals 5, 6) 236 Ω (terminals 1, 6) HART
Line fault detection can be switched on/off for each channel via configuration tool , configurable via configuration tool
ATEX approval BVS 11 ATEX E 093X
Open-circuit factory setting: < 1 mA configurable between 0 ... 26 mA
Short-circuit factory setting: > 22 mA configurable between 0 ... 26 mA
Influence of ambient temperature 0.1 %/10 K of the signal range
Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Interface manufacturer-specific bus to standard com unit
Coding optional mechanical coding via front socket
Occupied slots 1
Number of channels 1
Field device pressure converter
Field device [2] flow converter
Field device [3] level converter
Field device [4] Temperature Converter
Transmitter supply voltage min. 15 V at 20 mA ; 21.5 V at 4 mA
HART communication yes
HART secondary variable yes
After calibration 0.1 % of the signal range at 20 °C (68 °F)
Refresh time 100 ms
Environmental test EN 60068-2-14:2009
Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V
Lloyd Register 15/20021
Bureau Veritas Marine 22449/B0 BV
American Bureau of Shipping T1450280/UN