Type Z & Ex pzc purge and pressurization system 7500-MTD-PMSW-01

Type Z & Ex pzc purge and pressurization system 7500-MTD-PMSW-01
Type Z & Ex pzc purge and pressurization system 7500-MTD-PMSW-01

Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ

артикул: 97799
Под заказ
Запрос цены

Доставка в любой регион России транспортной
компанией на Ваш выбор

  • Must be used in conjunction with an EPV-7500-* vent
  • Panel mount, square panel
  • Universal power: AC or DC
  • Touch screen display with LEDs for easy visual indication
  • Easy setup with pre-set purge programs for your application
  • Automatic pressure compensation with digital manifold
  • Rugged, corrosion-resistant housing
  • Global third-party approvals for Class I, II, Div. 2 and Zone 2/22
  • Manual valve, no electrical power requirement
  • Purge and pressurization valving in one device
Параметр Значение
Общие характеристики
Артикул 97799
Материал AISI 316 (1.4401), 304, or 18-8 stainless steel A380, A356, 6061-T6 aluminum casting Bisco® HT-800 medium cellular silicone
Ambient temperature Ambient temperature ranges depend on the T class. See the certificates.
Storage temperature -40 ... 80 °C (-40 ... 176 °F)
Degree of protection Mounting to enclosure Type 4X / IP66
Mass 2.5 kg (5 lb 10 oz)
Operating mode fully automatic (FA)
Marking II 3 G Ex ec nC [pzc] IIC T6...T4 Gc II 3 D Ex tc [pzc] IIIC T60 °C ... T80 °C Dc
IECEx approval Ex ec nC [pzc] IIC T6...T4 Gc Ex tc [pzc] IIIC T60 °C ... T80 °C Dc
Supplementary information Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Series 7500
Hazardous environment gas or dust
cULus Class I, Division 2, Groups A, B, C, D T4 (-40 °C ≤ Ta ≤ 70 °C) Class I, Division 2, Groups A, B, C, D T5 (-40 °C ≤ Ta ≤ 65 °C) Class I, Division 2, Groups A, B, C, D, T6 (-40 °C ≤ Ta ≤ 50 °C) Class II, Division 2, Groups F, G T4 (-40 °C ≤ Ta ≤ 70 °C) Class II, Division 2, Groups F, G T5 (-40 °C ≤ Ta ≤ 65 °C) Class II, Division 2, Groups F, G T6 (-40 °C ≤ Ta ≤ 50 °C)
Directive 2014/30/EU EN 61326-1:2013 , FCC CFR 47, part 15, subpart B: 2017, Class A ICES-003, Issue 6:2016, Class A ITE
Directive 2011/65/EU (RoHS) EN 50581:2012
Directive 2014/34/EU IEC/EN 60079-0 , IEC/EN 60079-2 , IEC/EN 60079-7 , IEC/EN 60079-15 , IEC/EN 60079-31 Supplements: EN 61010-1:2010, EN 61326-3-2:2008, EN 61000-6-2:2005
Equipment architecture max. enclosure size 450 ft (12.7 m ) For complete technical data, see the 7500 Control Unit and 7500-MAN-MV-01 datasheets