Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 97793 |
Материал | Makrolon® GP-V polycarbonate AISI 316 (1.4401), 304, or 18-8 stainless steel A380, A356, or 6061-T6 aluminum Bisco® HT-800 medium cellular silicone SAE 304 stainless steel 6061-T6 aluminum |
Ambient temperature | Ambient temperature ranges depend on the T class. See the certificates. |
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) |
Degree of protection | Type 4X , IP66 |
Connection | K3, terminals, L1 powered contact |
Mass | 710 g (1 lb 10 oz) |
Rated voltage | 20 ... 30 V DC at 0.1 A 90 ... 250 V AC , 50 ... 60 Hz at 0.04 A without solenoid valve Supply voltage can be line-to-line or line-to-neutral, single phase OVC II |
Power consumption | max. 2.7 W / 7.3 VA without valve |
Relative humidity | 5 ... 90 %, non-condensing |
Altitude | max. 2000 m |
Operating mode | fully automatic (FA) |
Marking | II 3 G Ex ec nC [pzc] IIC T6...T4 Gc II 3 D Ex tc [pzc] IIIC T60 °C ... T80 °C Dc |
Output type | solenoid manifold, contact |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s , all axes |
Dimensions | 150 x 100 x 50 mm (5.9 x 4 x 2 in) |
Connection type | electrical: 2 x 1/2 inch NPTF (open from factory) 1 x M12 opening (plugged from factory) pneumatic: high-pressure port - 1/8 in NPTF, low-pressure port - 1/8 in NPTF |
IECEx approval | Ex ec nC [pzc] IIC T6...T4 Gc Ex tc [pzc] IIIC T60 °C ... T80 °C Dc |
Supplementary information | Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Series | 7500 |
Hazardous environment | gas or dust |
LED indication | K1: Green - Contact K1 is energized (enclosure contacts) K2: Amber - Contact K2 is energized (alarm/control contacts) P/SV: Blue - Safe pressure P1 (minimum enclosure pressure) P/SV: Amber - Solenoid manifold is energized (purging/pressure compensation) |
Protective gas supply | compressed air or inert gas, 5 µm filter, free from oil |
Safe pressure | 0.25 in wc (0.63 mbar) minimum for gas 0.65 in wc (1.63 mbar) minimum for dust |
Enclosure pressure | 0 ... 10 in wc (0 ... 24.8 mbar) |
Impact resistance | 30 g, 11 ms, all axes |
cULus | Class I, Division 2, Groups A, B, C, D T4 (-40 °C ≤ Ta ≤ 70 °C) Class I, Division 2, Groups A, B, C, D T5 (-40 °C ≤ Ta ≤ 65 °C) Class I, Division 2, Groups A, B, C, D, T6 (-40 °C ≤ Ta ≤ 50 °C) Class II, Division 2, Groups F, G T4 (-40 °C ≤ Ta ≤ 70 °C) Class II, Division 2, Groups F, G T5 (-40 °C ≤ Ta ≤ 65 °C) Class II, Division 2, Groups F, G T6 (-40 °C ≤ Ta ≤ 50 °C) |
Contact loading | 0.5 A at 250 V AC , 0.5 A at 30 V DC, relays must be externally fused |
Pressure requirement | supply pressure: 20 ... 120 psig (1.4 ... 8.2 bar) |
Inrush current | 5 A |
Directive 2014/30/EU | EN 61326-1:2013 , FCC CFR 47, part 15, subpart B: 2017, Class A ICES-003, Issue 6:2016, Class A ITE |
Directive 2011/65/EU (RoHS) | EN 50581:2012 |
Directive 2014/34/EU | IEC/EN 60079-0 , IEC/EN 60079-2 , IEC/EN 60079-7 , IEC/EN 60079-15 , IEC/EN 60079-31 Supplements: EN 61010-1:2010, EN 61326-3-2:2008, EN 61000-6-2:2005 |
Equipment architecture | max. enclosure size 450 ft (12.7 m ) |
Accuracy | pressure sensing: ± 0.125 in wc (0.31 mbar) timers: ± 5 % |