Для оформления заявки добавьте оборудование
в корзину и сформируйте заказ
Доставка в любой регион России транспортной
компанией на Ваш выбор
Параметр | Значение |
Общие характеристики | |
Артикул | 45354 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) at T4 -20 ... 40 °C (-4 ... 104 °F) at T6 |
Degree of protection | IP65 |
Connection | SV1, terminals 16, 17, 18 |
Housing | polyester |
Mass | approx. 1.4 kg (3.1 lb) |
Rated voltage | 230 VAC - 230 VAC, 48 ... 62 Hz ± 10% 115 VAC - 115 VAC, 48 ... 62 Hz ± 10% 24 VDC - 24 VDC ± 10% |
Power consumption | 230 VAC - 2.3 VA (without digital valve) 115 VAC - 2.3 VA (without digital valve) 24 VDC - 2.5 W (without digital valve) |
Relative humidity | 5 ... 95 %, noncondensing |
Operating mode | fully automatic (FA) |
Cable | Cross section: 16 to 20 AWG (0.5 to 1.5 mm ) Strip length: 0.31 to 0.35 inches (8 to 9 mm) Cross section: 16 to 20 AWG (0.5 to 1.5 mm ) Strip length: 0.35 inches (9 mm) Cross section: 18 to 24 AWG (0.25 to 1.0 mm ) Strip length: 0.33 to 0.37 inches (8.5 to 9.5 mm) |
Marking | II 3 G Ex nA nC [pz] II T4 -20 °C to +60 °C II 3 G Ex nA nC [pz] II T6 -20 °C to +40 °C II 3 D Ex tD A22 [pD] IP64 T70°C |
Output type | digital valve, (1) SPDT, powered contacts from power line |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s , all axes |
Dimensions | 140 x 120 x 90 mm (5.5 x 4.7 x 3.5 inch) |
EU-type examination certificate | EPS 10 ATEX 1263 , for additional certificates see www.pepperl-fuchs.com |
IECEx approval | Ex nA nC [pz] IIC T4 Gc Ex nA nC [pz] IIC T6 Gc Ex tc [p] IIIC T70 °C Dc IP64 File no: IECEx EPS 11.0010 |
Input type | temperature input |
Number of volume exchanges | min. 5 |
Hazardous environment | gas or dust |
Protective gas supply | instrument grade air or inert gas |
Safe pressure | - gas 0.25 mbar (0.1" H O) (Zone 2) - dust 0.5 mbar (0.2" H O) (Zone 22) |
Purge flow rate | - 3.0 mm orifice at 2 bar (29 psig): 105 l/min - 4.5 mm orifice at 2 bar (29 psig): 220 l/min |
Flow rate for leakage compensation | 0.3 l/min typ. (depends on enclosure seal) |
Impact resistance | 30 g, 11 ms, all axes |
Directive 94/9/EC | EN 60079-0:2006 , EN 60079-2:2007 , EN 60079-15:2005 , EN 61241-0:2004 , EN 61241-1:2004 , EN 61241-4:2006 |
Contact loading | 3 A |
Pressure requirement | min. 2 bar (29 psi) |
Inrush current | 5 A |
Shock resistance | EN 60068-2 |
Cable gland | 1.5 mm diameter max. wire size - power supply and contacts 0.13 ... 2.08 mm - Pt100 0.08 ... 1.31 mm |
Sensor type | Pt100, 2-wire connection |
Number of sensor connections | up to 3 sensors per unit |
Observation window | safety glass |