  • NFPA 496, ISA 12.4, and ATEX standards
  • Optional alarm output indicates air lock failure
  • Optional differential pressure switch for Class I, Group A-D, ATEX certified hazardous area locations
  • Type Ex [pz] certification for Zone 2 hazardous locations
  • Type Y system certified for Class I, Division 1 to Division 2
  • Type Z system certified for Class I, Division 2 to nonhazardous area
  • Enclosure volume up to 2.54 m3 (90 ft3)
Параметр Значение
Общие характеристики
Артикул 50773
Материал Regulator body: zinc w/enamel finish Regulator handle & bowl: polycarbonate Enclosure pressure gauge: alum. w/enamel finish Rapid Exchange gauge: poly & nickel plated Tube fitting: 316 SS forged body Tubing: 316 SS 1/4" .035 welded Fastener hardware: alum. & stainless steel System face plate: 316 14 ga #3 brush SS System mounting flange: 316 SS tumble finish Manifold body: anodized aluminum Manifold valves: 316 SS Mfr. ID nameplate: silkscreen Lexan
Ambient temperature -29 ... 49 °C (-20.2 ... 120.2 °F)
Connection Terminal blocks
Mass 3003-LPS-* 4.5 kg (10 lb) 3003-WPS* 6.8 kg (15 lb)
Marking LPS: II 3G Ex [pz] IIC T4 WPSA: II 3G Ex [pz] IIB+H2 T4
Output type Switch contacts
Connection type System supply port: 1/4" FPT Enclosure supply port: 1/2" FPT Enclosure reference fitting: 1/4" tube Switch conduit port size: 1/2" FPT
Hazardous environment gas
Protective gas supply instrument grade air or inert gas
Safe pressure Setpoint: 0.25" (6.35 mm) Flow rate: 0.1 - 3.5 SCFH (2.8 - 99 l /hr)
Purge flow and enclosure pressure rate 12 SCFM /720 SCFH (340 l /m / 20390 l /hr) (With regulator set to 60 psi min. during exchange)
Directive 94/9/EC *-LPS-* : EN 60079-2: 2004 EN 60079-0: 2006
cULus Type Y LPS: Class I, Division 1, Groups A, B, C, D WPS: Class 1, Division 1, Groups C, D WPSA: Class I, Division 1, Groups A, B, C, D Type Z and Ex [pz] LPS: Class I, Division 2, Groups A, B, C, D WPS: Class 1, Division 2, Groups C, D WPSA: Class I, Division 2, Groups A, B, C, D
Output I -WPS-
Contact loading 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 mA power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 watts
Output II -WPSA-
Pressure requirement 80 - 120 psi (5.5 - 8.3 bar)
FM approval Type Y LPS: Class I, Division 1, Groups A, B, C, D WPS: Class 1, Division 1, Groups C, D WPSA: Class I, Division 1, Groups A, B, C, D Type Z and Ex [pz] LPS: Class I, Division 2, Groups A, B, C, D WPS: Class 1, Division 2, Groups C, D WPSA: Class I, Division 2, Groups A, B, C, D