  • Certified for Class I, Class II, Division I; Zone 1 / Zone 21 to nonhazardous
  • Intrinsically safe electrical/pneumatic manifold assembly
  • Intrinsically safe user interface for programming and monitoring the system
  • Enclosure volume up to 450 ft3 (12.1 m3)
  • Control Unit monitors system operation and controls enclosure power
  • Universal mounting (brackets included)
  • 316L stainless steel Type 4X enclosure
Параметр Значение
Общие характеристики
Артикул 39245
Материал Enclosure: 316L (UNS S31603) stainless steel Manifold valve: anodized 6082 aluminum Fittings: 316L (UNS S31603) stainless steel
UL approval 6000 Main control unit with housing 6000-xx-S2-UN-xx-xx: cULus Class I, Division 1, Groups A,B,C,D T4 (-20 °C ≤ Ta ≤ 60 °C) Class II, Division 1, Groups E,F,G T4 (-20 °C ≤ Ta ≤ 50 °C) Class I, Zone 1, Group IIC T4 (-20 °C ≤ Ta ≤ 60 °C) Class II, Zone 21, Group IIIC T60 °C (-20 °C ≤ Ta ≤ 50 °C) [Ex i] Associated Equipment Ex db [ib pxb] IIC T4 (-20 °C ≤ Ta ≤ 60 °C) Ex db tb [ib pxb] IIIC T4 (-20 °C ≤ Ta ≤ 50 °C) 6000 Main control unit kit version 6000-xx-S2-UN-CK-xx: cULus Class I, Division 1, Groups A,B,C,D T4 (-20 °C ≤ Ta ≤ 60 °C) Class II, Division 1, Groups E,F,G T4 (-20 °C ≤ Ta ≤ 60 °C) Class I, Zone 1, Group IIC T4 Class II, Zone 21, Group IIIC T60 °C [Ex i] Associated Equipment Ex db [ib pxb] IIC T4 X (-20 °C ≤ Ta ≤ 60 °C) Ex db [ib pxb] IIIC T4 X (-20 °C ≤ Ta ≤ 60 °C) User interface 6000-UIC-xx: cULus (-20 °C ≤ Ta ≤ 60 °C) Class I, Division 1, Groups A,B,C,D T4 Class I, Zone 1, Group IIC T4 Ex i Intrinsically safe
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -30 ... 80 °C (-22 ... 176 °F)
Degree of protection Type 4X , IP66
Connection M8 connector, 4-pin
Mass -WH- 11.4 kg (25 lb) -CK- 7.2 kg (16 lb)
Rated voltage 90 ... 264 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC
Relative humidity 5 ... 95 %, noncondensing
Operating mode manual, semi-automatic, or fully automatic - programmable
Marking 6000 main control unit with housing 6000-xx-S2-UN-xx-xx: ATEX UL/Demko 07 ATEX 0705753X II 2 G Ex db [ib pxb] IIC T4 Gb (-20 °C ≤ Ta ≤ 60 °C) II 2 D Ex ib tb [ib pxb] IIIC T60°C Db (-20 °C ≤ Ta ≤ 50 °C) 6000 main control unit kit version 6000-xx-S2-UN-CK-xx: ATEX UL/Demko 07 ATEX 0705753X II 2 G Ex db [ib pxb] IIC T4 Gb (-20 °C ≤ Ta ≤ 60 °C) II 2 D Ex tb [ib pxb] IIIC T80°C Db (-20 °C ≤ Ta ≤ 60 °C) User interface 6000-UIC-xx: ATEX UL/Demko 07 ATEX 0705753X II 2 G Ex ib [pxb] IIC T4 Gb
Output type Dry contacts (2) SPST, NO
Vibration resistance 5 ... 100 Hz , 1 g, 12 m/s , all axes
Dimensions 183 x 367.5 x 152.5 mm (7.20 x 14.45 x 6.00 inch)
Connection type Pneumatic : Inlet fitting to manifold: 3/8" NPT (female) Outlet fitting from manifold: 3/8" bulkhead fitting (provided)
LED indicator Safe pressure: Blue - safe pressure is achieved Enclosure power: Green - power on; Red - power off Rapid exchange: Blue - purging is running System bypass: Yellow - bypass is activated Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - 6000 series system fault
IECEx approval 6000 Main Control unit with housing 6000-xx-S2-UN-xx-xx: IECEx UL 08.0003X Ex db [ib pxb] IIC T4 Gb (-20 °C ≤ Ta ≤ 60 °C) Ex db tb [ib pxb] IIIC T60 °C Db (-20 °C ≤ Ta ≤ 50 °C) 6000 Main control unit kit version 6000-xx-S2-UN-CK-xx: IECEx UL 08.0003X Ex db [ib pxb] IIC T4 Gb (-20 °C ≤ Ta ≤ 60 °C) Ex db [ib pxb] IIIC T80 °C Db (-20 °C ≤ Ta ≤ 60 °C) User interface 6000-UIC-xx: IECEx UL 08.0003X Ex ib [pxb] IIC T4 Gb
Input type intrinsically safe
Number of volume exchanges 4 to 19
Hazardous environment gas, dust, gas and dust
Protective gas supply instrument grade air or inert gas
Safe pressure Gas: 0.25" wc (6.4 mm wc) (0.625 mbar) (62 Pa) Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) (162 Pa) Gas and Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) ( 162 Pa)
Purge flow rate Maximum flow rate measurement for enclosure size (enclosure volume:flow rate): < 20 ft³ (0.57m³): 5, 12 SCFM (56, 141, 340 l/min), or dynamic 20 ... 30 ft³ (0.57 ... 0.85 m³): 5, 12, 20 SCFM (56, 141, 340, 565 l/min), or dynamic > 30 ft³ (0.85m³): 5, 12, 20, 30 SCFM (56, 141, 340, 565, 850 l/min), or dynamic
Purge flow and enclosure pressure rate With EPV-6000-xx-01, EPV-6000-xx-02 5 SCFM @ 1.5" wc, (141 l/min @ 3.7 mbar) 12 SCFM @ 2.0" wc, (340 l/min @ 5.0 mbar) 20 SCFM @ 2.7" wc, (565 l/min @ 6.7 mbar) 30 SCFM @ 4.1" wc, (850 l/min @ 10.2 mbar) With EPV-6000-xx-03, EPV-6000-xx-04 5 SCFM @ 2.1" wc, (141 l/min @ 5.2 mbar 12 SCFM @ 2.6" wc, (340 l/min @ 6.5 mbar) 20 SCFM @ 4.1" wc, (565 l/min @ 10.2 mbar) 30 SCFM @ 5.3" wc, (850 l/min @ 13.2 mbar) With EPV-6000-xx-05, EPV-6000-xx-06 5 SCFM @ 1.8" wc, (141 l/min @ 4.5 mbar) 12 SCFM @ 2.9" wc, (340 l/min @ 7.3 mbar) 20 SCFM @ 7.4" wc, (565 l/min @ 18.5 mbar)
Flow rate for leakage compensation Depends on enclosure seal. With EPV-6000-xx-01, EPV-6000-xx-02 0.35 SCFM @ 0.25" wc (10.0 l/min @ 6.3 mbar) 1.0 SCFM @ 0.75" wc (28.0 l/min @ 1.9 mbar) With EPV-6000-xx-03, EPV-6000-xx-04 0.22 SCFM @ 0.25" wc (6.2 l/min @ 6.3 mbar) 0.58 SCFM @ 0.75" wc (16.4 l/min @ 1.9 mbar) With EPV-6000-xx-05, EPV-6000-xx-06 0.15 SCFM @ 0.25" wc (4.2 l/min @ 6.3 mbar) 0.35 SCFM @ 0.75" wc (10.0 l/min @ 1.9 mbar)
Impact resistance 30 g, 11 ms, all axes
Directive 94/9/EC IEC/EN 60079-0 IEC/EN 60079-1 IEC/EN 60079-2 IEC/EN 60079-7 IEC/EN 60079-11 IEC/EN 60079-31
Output I AUX 1
Contact loading 8 A @ 240 VAC / 120 VAC resistive load 8 A @ 24 VDC
Output II AUX 2
Pressure requirement 20 ... 120 psig (1.4 ... 8.3 bar) (138 ... 827 kPa) regulated
Input I Inputs 1, 2, 3, 4: contact input, 5 VDC @ 2 mA
Input II Temperature inputs
Inrush current 5 A
Cable gland 4 - M16 x 1.5 cable gland
Sensor type 6000-TEMP
Input III EPV-6000 Vent
Input IV User interface module
Output III ENC_1, ENC_2 (protected enclosure contacts)