Параметр | Значение |
Общие характеристики | |
Артикул | 98854 |
Материал | inlet and outlet: 1 1/4 inch NPTF, 316 stainless steel internal piping: brass bulkhead fittings: 316 stainless steel gate valve: bronze, Grafoil seals purging valve: 316 stainless steel, PTFE seals pilot valve: 1/4 inch NPTF, 316 stainless steel solenoid valve: aluminum housing: 303, 304 L stainless steel |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -30 ... 80 °C (-22 ... 176 °F) |
Degree of protection | IP66 |
Connection | M8 connector, 4-pin (provided) |
Mass | 40 kg (88 lb) |
Rated voltage | 100 ... 250 V AC, 48 ... 62 Hz / 0.2 A 20 ... 30 V DC / 0.6 A |
Relative humidity | 5 ... 95 %, noncondensing |
Operating mode | manual, semi-automatic, or fully automatic - programmable |
Marking | II2G Ex db eb ib [ib Gb][pxb Gb] IIC T4 Gb |
Output type | Dry contacts (2) SPST, NO |
Vibration resistance | EN 60068-2-6 |
Dimensions | 558 mm x 762 mm x 213 mm (22 in x 30 in x 8.4 in) |
Connection type | Terminals |
Core cross-section | see manual |
Cable entry | 3 x M16 holes, plugs that are included are not hazardous-location rated 4 x M20 holes, plugs that are included are not hazardous-location rated |
IECEx approval | IECEx CML 19.0156X Ex db eb ib [ib Gb][pxb Gb] IIC T4 Gb |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Supplemental Standards : EN 61010-1:2010 |
Input type | intrinsically safe |
Series | 6100 Series |
Number of volume exchanges | 4 to 19 |
Hazardous environment | gas |
Power | Ex e terminal blocks |
LED indication | Safe pressure: Blue - safe pressure is achieved Enclosure power: Green - power on; Red - power off Rapid exchange: Blue - purging is running System bypass: Yellow - bypass is activated Alarm fault: Red (blinking) - any alarm input detected; Red (solid) - fault |
Protective gas supply | regulated and filtered air or inert gas |
Safe pressure | 0.25 in wc (6.4 mm wc) (0.625 mbar) minimum for 6100-MP-LPP-* |
Purge flow and enclosure pressure rate | 2000 l/m ... 14000 l/m see EPV-6100 datasheet for flow rate steps |
Impact resistance | EN 60068-2-27 |
Output I | AUX 1 |
Contact loading | 8 A at 240 V AC / 120 V AC resistive load 8 A at 24 V DC |
Output II | AUX 2 |
Pressure requirement | regulated side: 20 ... 120 psig (1.4 ... 8.3 bar) unregulated side: 60 ... 120 psig (4.1 ... 8.3 bar) |
Input I | Inputs 1, 2: contact input, 5 V DC at 2 mA Warning: inputs 1, 2, 3, and 4 must be used with the SRM-6000 for tested EMC immunity |
Input II | temperature hub, temperature inputs |
Inrush current | 72 A |
Directive 2014/30/EU | EN 61326-1:2013 |
Directive 2011/65/EU (RoHS) | EN 50581:2012 |
Certificate | CML 19 ATEX 1425X |
Directive 2014/34/EU | EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-2:2014 EN 60079-7:2015 EN 60079-11:2012 |
Sensor type | EPV-6100-LPP |
Input III | low pressure sensor |
Input IV | User interface module |
Output III | enclosure 1 and 2 |
Valve flows | pressurization valve: manual gate valve purging valve: pilot drive angle seat valve pilot valve: intrinsically safe solenoid valve |