Параметр | Значение |
Общие характеристики | |
Артикул | 84884 |
Control elements | DIP-switch |
Switching frequency | < 3 Hz with disabled internal fault detection < 0.5 Hz with enabled internal fault detection |
UL approval | E106378 |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating. |
Degree of protection | IP20 |
Connection | screw terminals |
Mass | approx. 134 g |
Rated voltage | 19 ... 26.4 V DC |
Power consumption | < 1.7 W , includes the power consumption of the digital input , see derating curves |
Electromagnetic compatibility | NE 21:2012 , EN 61326-3-2:2008 , EN 61326-3-1:2008 |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Marking | II 3G Ex nC ec IIC T4 Gc [device in zone 2] |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 |
Mechanical life | 10 switching cycles |
Labeling | space for labeling at the front |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Rated current | 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) |
Contact loading | 30 V DC/ 0.5 A resistive load |
Inrush current | < 200 mA after 100 µs |
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Certificate | PF 17 CERT 4305 X |
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2015 , EN 60079-15:2010 |
Safety Integrity Level (SIL) | SIL 3 |
Display elements | LEDs |
Optional accessories | - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-GY(-UPR-03) |
Power dissipation | < 3.3 W at 5 A , see derating curves |
Configuration | via DIP switches |
Input current | 35 mA at 24 V DC , max. 44 mA at 19 V DC , with enabled internal fault detection |
Signal level | 0-signal: -5 ... 5 V DC 1-signal: 19 ... 26.4 V DC |
Connection side | field side |
Reaction time | < 2 s |
Line fault detection | low voltage < 5 V DC undercurrent: 10 mA DC; overcurrent: 2.2 A DC (relay energized) breakage: 8.2 kΩ; short-circuit: 11 Ω (load, relay de-energized) |
Signal type | Digital Output |
Minimum switch current | 10 mA |
Input/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 V |
Protection against electrical shock | EN 61010-1:2010 |
Test pulse length | max. 2 ms from DO card |
Output/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 V |
Pulse/Pause ratio | min. 150 ms / min. 150 ms with disabled internal fault detection min. 1 s / min. 1 s with enabled internal fault detection |
Connectable voltage | 8 ... 60 V DC |
Input/fault indication output | basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V |